Structural Findings in the Brain MRI of Patients with Acute Carbon Monoxide Poisoning
Authors
Abstract:
Background: Carbon monoxide (CO) poisoning may lead to hypoxic/anoxic injury and eventually ischemic encephalopathy. Magnetic resonance imaging (MRI) has a well-recognized role in assessment of the severity of brain damage caused by CO poisoning. In this study, we aimed to present and analyze the structural abnormalities in the brain MRI and especially in diffusion weighted MRI (DWI) images in a series of patients with acute CO poisoning. Methods: This cross-sectional observational study was performed on patients with moderate to severe CO poisoning admitted to Mashhad Medical Toxicology Center of Imam Reza Hospital, Mashhad, Iran, during autumn and winter 2013. After stabilization, patients underwent brain MRI. T1 weighted, T2 weighted and FLAIR images in sagittal, axial and coronal sections, and DWI in axial sections were performed for each patient. Results: Eighteen patients (77.8% men) were enrolled in this study with median age of 29.5 years. Eleven patients (61.1%) had abnormal MRI signals and in 7 cases no abnormality or nonspecific abnormalities were detected. The most common involved region in brain MRI was white matter (38.9%) followed by globus pallidus (33.3%). Patients with signal abnormality in brain MRI had significantly longer duration of exposure to CO compared to those without signal changes (10.6 ± 6.2 h vs. 3.4 ± 2.8 h, P = 0.011). Nine patients had restricted diffusion in DWI. Patients with restricted diffusion in DWI had also longer duration of exposure to CO compared to patients with normal DWI (12.1 ± 5.5 h vs. 3.5 ± 2.9 h, P = 0.001). Conclusion: The white matter and globus pallidus were the most common affected regions in brain following acute CO poisoning. Signal abnormalities and restricted diffusion in MRI were correlated with duration of exposure to CO but not with the carboxyhemoglobin levels.
similar resources
structural findings in the brain mri of patients with acute carbon monoxide poisoning
background: carbon monoxide (co) poisoning may lead to hypoxic/anoxic injury and eventually ischemic encephalopathy. magnetic resonance imaging (mri) has a well-recognized role in assessment of the severity of brain damage caused by co poisoning. in this study, we aimed to present and analyze the structural abnormalities in the brain mri and especially in diffusion weighted mri (dwi) images in ...
full textAcute Carbon Monoxide Poisoning in a Poisoning Referral Center
Bachground: Acute carbon monoxide poisoning (COP) is a common problem that occurs more frequently during winter and leads to serious complications. In our Poisoning Referral Center, the incidence and complications of acute COP has not been evaluated previously. Therefore we designed a study to evaluate its significance in our center. Methods & Materials: 111 cases of acute COP admitted duri...
full textBrain MRI Findings of Carbon Disulfide Poisoning
OBJECTIVE To evaluate the findings of brain MRI in patients with carbon disulfide poisoning. MATERIALS AND METHODS Ninety-one patients who had suffered carbon disulfide poisoning [male:female=87:4; age, 32-74 (mean 53.3) years] were included in this study. To determine the extent of white matter hyperintensity (Grade 0-V) and lacunar infarction, T2-weighted MR imaging of the brain was perform...
full textBrain MRI Findings in Children with Acute Lymphoblastic Leukemia
Background: Patients with leukemia are facing more complications in order to achieve longer survival. We aimed to evaluate the frequency of central nervous system abnormalities (CNS) on MRI of children with acute lymphoblastic leukemia (ALL). Methods: Sixty-six children with diagnosis of ALL aged 2-18 years were recruited. Non-contrast sequences of brain MRI in addition to diffusion weighted i...
full textAcute carbon monoxide poisoning: diffusion MR imaging findings.
During the acute stage of carbon monoxide poisoning, diffusion MR images obtained at b=1000 s/mm2 revealed high signal intensity lesions in the white matter, consistent with restricted diffusion. Low apparent diffusion coefficient values (0.18-0.34 x 10(-3) mm2/s) were noted in the affected white matter regions. Follow-up MR imaging performed 16 days later revealed disappearance of white matter...
full textMy Resources
Journal title
volume 3 issue 3
pages 124- 129
publication date 2014-09-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023