Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

Authors

  • Elham Farzaneh Bahalgerdy Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
Abstract:

Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on OCT and test images. Objective evaluation of both types of images was performed, using various image metrics such as peak signal-to-noise ratio (PSNR), root mean square error, correlation coefficient and elapsed time. For the purpose of recovery, Kuan filter was used as an input for edge enhancement. Also, a spatial filter was applied to improve image quality. Results The obtained results were presented as statistical tables and images. Based on statistical measures and visual quality of OCT images, Enhanced Lee filter (3×3) with a PSNR value of 43.6735 in low noise variance and Kuan filter (3×3) with a PSNR value of 37.2850 in high noise variance showed superior performance over other filters. Conclusion Based on the obtained results, by using speckle reduction filters such as Enhanced Lee and Kuan filters on OCT images, the number of compounded images, required to achieve a given image quality, could be reduced. Moreover, use of Kuan filters for promoting the edges allowed smoothing of speckle regions, while preserving image tissue texture.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

speckle noise reduction for the enhancement of retinal layers in optical coherence tomography images

introduction one of the most important pre-processing steps in optical coherence tomography (oct) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of oct images. materials and methods the present study focused on speckle noise reduction and edge detection techniques. statistical filters with different masks and noise variances were applied on ...

full text

Speckle noise reduction in optical coherence tomography of paint layers.

We present and characterize a sequential angular compounding method for reducing speckle contrast in optical coherence tomography images of paint layers. The results are compared with postprocessing methods, and we show that the compounding technique can improve the speckle contrast ratio in B-scans by better than a factor of 2 in exchange for a negligible loss of resolution. As a result, image...

full text

Efficient reduction of speckle noise in Optical Coherence Tomography.

Speckle pattern, which is inherent in coherence imaging, influences significantly axial and transversal resolution of Optical Coherence Tomography (OCT) instruments. The well known speckle removal techniques are either sensitive to sample motion, require sophisticated and expensive sample tracking systems, or involve sophisticated numerical procedures. As a result, their applicability to in viv...

full text

General Bayesian estimation for speckle noise reduction in optical coherence tomography retinal imagery.

An important image post-processing step for optical coherence tomography (OCT) images is speckle noise reduction. Noise in OCT images is multiplicative in nature and is difficult to suppress due to the fact that in addition the noise component, OCT speckle also carries structural information about the imaged object. To address this issue, a novel speckle noise reduction algorithm was developed....

full text

Speckle reduction in optical coherence tomography images using tissue viscoelasticity.

We present a technique to reduce speckle in optical coherence tomography images of soft tissues. An average is formed over a set of B-scans that have been decorrelated by viscoelastic creep strain. The necessary correction for the deformation-induced spatial distortions between B-scans is achieved through geometrical co-registration using an affine transformation. Speckle reduction by up to a f...

full text

Speckle Noise Reduction and Segmentation on Polarization Sensitive Optical Coherence Tomography Images

The retinal layers of a monkey were imaged using a Polarization Sensitive Optical Coherence Tomography (PS-OCT) system in an effort to develop a clinically reliable automatic diagnostic system for glaucoma. Glaucoma is characterized by the progressive loss of ganglion cells and axons in the retinal nerve fiber layer (RNFL). Automatic segmentation of the RNFL from the PS-OCT images is a fundamen...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 12  issue 3

pages  178- 188

publication date 2015-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com