Specific Fast Response CH4 Gas Sensor Based on Metal Oxide, Tungsten Carbide /SnO2Core-Shell Modified Interdigitated Electrode

Authors

  • M.H. Sheikhi School of Electrical and Computer engineering, Shiraz University, I. R. Iran
  • M.M. Doroodmand Department of Chemistry, College of Sciences, Shiraz University, I. R. Iran
  • S. Nikmanesh School of Electrical and Computer engineering, Shiraz University, I. R. Iran
Abstract:

In this study, a specific CH4 sensor is fabricated based on interdigitated electrode that modified with core-shell of tungsten carbide/tin oxide (WC/SnO2) nanoparticles by wet chemical method in different percents of carbon and tungsten. The morphology of wet chemical-synthesized WC/SnO2 core-shell was evaluated by different methods such as patterned X-ray diffraction (XRD), and particle size analyzer (PSA). The fabricated sensor is selected as specific nanomaterial for CH4 detection. In the fabricated CH4 sensor, change in resistance of the sensor was considered as the detection system. In this study, figures of merits such as linearity, specificity, response time were also evaluated. No serious interference was evaluated for different foreign gases, introduced to a certain concentration of CH4. The reliability of the fabricated CH4 sensor was evaluated via measuring CH4 in several gaseous samples. A fast response time about 8s and recovery time 11s has obtained from (5.0% WC-doped SnO2).

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

specific fast response ch4 gas sensor based on metal oxide, tungsten carbide /sno2core-shell modified interdigitated electrode

in this study, a specific ch4 sensor is fabricated based on interdigitated electrode that modified with core-shell of tungsten carbide/tin oxide (wc/sno2) nanoparticles by wet chemical method in different percents of carbon and tungsten. the morphology of wet chemical-synthesized wc/sno2 core-shell was evaluated by different methods such as patterned x-ray diffraction (xrd), and particle size a...

full text

Efficient Determination of Butylated Hydroxyanisole Using an Electrochemical Sensor Based on Cobalt Oxide Nanoparticles Modified Electrode

A simple and reliable electrochemical sensor based on cobalt oxide nanoparticles modified glassy carbon electrode (GCE/CoOxNPs) for determination of butylated hydroxyanisole is presented here. The nanoparticles were fabricated by electrodepositing method. The modified electrode shows excellent catalytic activity toward butylated hydroxyanisole oxidation in pH 12.0 phosphate buffer solution (PBS...

full text

Reduced Graphene Oxide Modified the Interdigitated Chain Electrode for an Insulin Sensor

Insulin is a key regulator in glucose homeostasis and its deficiency or alternations in the human body causes various types of diabetic disorders. In this paper, we present the development of a reduced graphene oxide (rGO) modified interdigitated chain electrode (ICE) for direct capacitive detection of insulin. The impedance properties of rGO-ICE were characterized by equivalent circuit modelin...

full text

Potential of Metal Reactive Oxides for Development of 4H-Silicon Carbide-based Metal-Oxide- Semiconductor Gas Sensor

The escalating demand in automotive industry nowadays has evoked civic awareness towards environmental issues brought by the exhaust emissions through fossil fuel combustion engine or hydrogen leak in fuel cell vehicles. Metal-oxide-semiconductor (MOS)-based gas sensors that were able to monitor the changes of oxygen and hydrogen leak were required. By replenishing the conventional silicon-MOS-...

full text

TiO2 based surface acoustic wave gas sensor with modified electrode dimensions for enhanced H2 sensing application

The design and optimization of nanostructure-based surface acoustic wave (SAW) gas sensor is analyzed based on TiO2 sensing layer and modified electrode dimensions. The sensitivity of the gas sensor depends upon the type of sensing layer used and active surface area obtained by varying the aspect ratio. The performance of the sensor is observed from 0.1ppm to 100ppm concentration of ...

full text

efficient determination of butylated hydroxyanisole using an electrochemical sensor based on cobalt oxide nanoparticles modified electrode

a simple and reliable electrochemical sensor based on cobalt oxide nanoparticles modified glassy carbon electrode (gce/cooxnps) for determination of butylated hydroxyanisole is presented here. the nanoparticles were fabricated by electrodepositing method. the modified electrode shows excellent catalytic activity toward butylated hydroxyanisole oxidation in ph 12.0 phosphate buffer solution (pbs...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 11  issue 3

pages  209- 217

publication date 2015-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com