Solid Phase Extraction of Ultra Trace Amounts of Ni2+ by Dimethylglyoxime (DMG) Immobilized on Column

Authors

  • Farzaneh Shemirani Department of Chemistry, Faculty of Science, University of Tehran, P.O. Box 14155-6455 Tehran, I.R. IRAN
  • Mahdi Zamani Department of Chemistry, Faculty of Science, University of Tehran, P.O. Box 14155-6455 Tehran, I.R. IRAN
  • Mohammad Reza Jamali Department of Chemistry, Faculty of Science, University of Tehran, P.O. Box 14155-6455 Tehran, I.R. IRAN
Abstract:

A column of alumina modified with sodium dodecyl sulfate (SDS) and dimethylglyoxime (DMG) was prepared for the preconcentration of trace nickel from water samples for flame atomic absorption spectrometry (FAAS) determinations. Under optimized conditions (pH=7.0; flow rate: 20 mlmin-1) nickel was retained on the column. The nickel collected on the column was eluted with 5 mL of 1 M nitric acid. Recovery was greater than 98%. A concentration factor of 200 can be achieved by passing 1000mL of sample through the column. The relative standard deviation (10 replicate analyses) at the 200 ngml-1 level for nickel was 2.2% and the corresponding limit of detection (based on 3σ) was 0.82 ngml-1. The method was applied to the determination of nickel in row solution for nickel plating.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

solid phase extraction of ultra trace amounts of ni2+ by dimethylglyoxime (dmg) immobilized on column

a column of alumina modified with sodium dodecyl sulfate (sds) and dimethylglyoxime (dmg) was prepared for the preconcentration of trace nickel from water samples for flame atomic absorption spectrometry (faas) determinations. under optimized conditions (ph=7.0; flow rate: 20 mlmin-1) nickel was retained on the column. the nickel collected on the column was eluted with 5 ml of 1 m nitric acid. ...

full text

Application of graphene oxide- magnetic nanoparticle for solid phase extraction of trace amounts of cadmium ions in environmental samples

Abstract In this work, Fe3O4-graphene oxide nanocomposite (GO-Fe3O4) was prepared as effective absorbent for magnetic solid phase extraction (MSPE) of trace quantities of cadmium ions in environmental water and rice samples using 1, 2-dihydroxy anthraquinone-3-sulphonic acid, sodium salt (Alizarin red S) and flame atomic absorption spectrometry (FAAS). The   GO-Fe3O4 was characterized by scanni...

full text

Extraction and determination of trace amounts of chlorpromazine in biological fluids using magnetic solid phase extraction followed by HPLC

A simple, rapid and sensitive method termed as magnetic solid phase extraction (MSPE) combined with high-performance liquid chromatography-ultraviolet detector (HPLC-UV) has been proposed for the determination of trace amounts of chlorpromazine (CPZ) in water, urine and plasma samples. The separation and determination was performed on a C18 column under the optimal chromatographic conditions. S...

full text

Solid-phase extraction, separation, and visible spectrophotometric determination of trace amounts of iron in water samples.

A simple and reliable method is presented for the rapid extraction, separation, preconcentration, and determination of iron as its bathophenanthroline complex by the use of octadecylsilica membrane disks and spectrophotometry. We evaluted extraction efficiency, the influence of sample matrix, type and optimum amount of extractant, flow rates of sample solution and eluent, pH, amounts of bathoph...

full text

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

full text

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 22  issue 2

pages  55- 59

publication date 2003-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023