Skin Dosimetry in Radiotherapy of Breast Cancer: a Comparison between EBT and EBT3 Radiochromic Films

Authors

  • F Akbari
  • M T Bahreyni Toosi
  • N Mohammadian
Abstract:

Objective: Radiochromic EBT3 film is a later generation of radiochromic films. The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer.Methods: A RANDO phantom was irradiated by a 6 MV Siemens Primus linac with medial and lateral fields of radiotherapy of breast cancer. Dosimetry was performed in various points in the fields using EBT and EBT3 films. Films were scanned by a Microtek color scanner. Dose values from two films in corresponding points were compared.Results: In the investigation of calibration, net optical density (NOD) of EBT radiochromic is more than the EBT3 radiochromic film. The highest percentage difference between NODs of two films is related to 0.75 Gy and equals to 14.19%. The lowest value is related to 0.2 Gy dose and is equal to 3.31%. The highest percentage difference between two films on the RANDO phantom in breast cancer fields is 13.51% and the minimum value is equal to 0.33%.Conclusion: From the comparison between the two films, most of the points show differences in dose in the measurements in fields of breast cancer radiotherapy. These differences are attributed to the thickness of the active layers, the overall thickness of the films, and the difference in the calibration fitted functions. The advantage of EBT film over EBT3 is a higher sensitivity; on the other hand EBT3 film allows to use its both sides in the scanning process and it is a new version of this film type. 

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

skin dosimetry in radiotherapy of breast cancer: a comparison between ebt and ebt3 radiochromic films

objective: radiochromic ebt3 film is a later generation of radiochromic films. the aim of this study is to compare ebt and ebt3 radiochromic films in radiotherapy fields of breast cancer. methods: a rando phantom was irradiated by a 6 mv siemens primus linac with medial and lateral fields of radiotherapy of breast cancer. dosimetry was performed in various points in the fields using ebt and ebt...

full text

Comparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy

Background: EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years.Objective: The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer.Methods: Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose was m...

full text

Comparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy

BACKGROUND EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years. OBJECTIVE The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. METHODS Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose wa...

full text

comparison of ebt and ebt3 radiochromic film usage in parotid cancer radiotherapy

background: ebt and ebt3 radiochromic films have been used in radiotherapy dosimetry for years. objective: the aim of the current study is to compare ebt and ebt3 radiochromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. methods: calibrations of ebt and ebt3 films were performed with identical setups using a 6 mv photon beam of a siemens primus linac. skin dose was...

full text

Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range

The objective of this study is to evaluate the suitability of recently introduced radiochromic film EBT3 for clinical dosimetry in the kilovoltage (kV) range. For this purpose, a kV X-ray irradiator, X RAD 320ix in the range 70 to 300 kVp, a clinical 60Co source, a 6 MV and an 18 MV X-ray clinical beam from a Varian linear accelerator were calibrated following AAPM dosimetry protocols. EBT3 fil...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 6  issue 2

pages  -

publication date 2016-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023