Simultaneous Spectrophotometric Determination of Heavy Metal Ions Using Several Chemometrics Methods: Effect of Different Parameters of Savitzky-Golay and Direct Orthogonal Signal Correction Filters

Authors

  • Ahmad Rouhollahi Department of Chemistry, Faculty of Sciences, K. N. Toosi University of Technology, Tehran, I. R. IRAN
  • Hossein Tavakoli Department of Chemistry, Faculty of Sciences, K. N. Toosi University of Technology, Tehran, I. R. IRAN
  • Jahanbakhsh Ghasemi Department of Chemistry, Faculty of Sciences, Razi University, Kermanshah, I. R. IRAN
  • Majid Hashemi Researches and Petroleum Engineering Center of Kermanshah, Kermanshah, I. R. IRAN
  • Mohammad Noroozi Researches and Petroleum Engineering Center of Kermanshah, Kermanshah, I. R. IRAN
  • Shahzad Nayebi Department of Chemistry, Faculty of Sciences, Razi University, Kermanshah, I. R. IRAN
Abstract:

Direct orthogonal signal correction(DOSC) and Savitzky-Golay filters (SGF) were applied as preprocessing methods on the original and first derivative absorbance data. Principle component regression (PCR), partial least squares (PLS) and iterative target transformation factor analysis (ITTFA), were used in spectrophotometric simultaneous determination of heavy divalent metal ions, lead, zinc,mercury and cadmium,using 4-(2-pyridylazo) resorcinol (PAR) as metallochromic indicator. The optimum values of the parameters for DOSC and SGF were obtained according to REP, R2 and RMSEP functions for calibration and prediction sets. The concentration for Hg2+, Pb2+, Zn2+ and Cd2+ ions in calibration set were varied between 0 - 12.24, 0 - 9.81, 0 - 0.87 and 0 - 3.96 ppm, respectively. The experimental calibration set was composed of 35 sample solutions and the 7 solutions as prediction set using a simple lattice (4,4) mixture design. The absorption spectra were recorded from 450 to 600 nm and absorbance data were autoscaled. The effect of pH on the sensitivity and selectivity was studied in the range of 1.00 - 11.00 and pH=7.50 was chosen according to net analyte signal (NAS) as a function of pH.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

simultaneous spectrophotometric determination of heavy metal ions using several chemometrics methods: effect of different parameters of savitzky-golay and direct orthogonal signal correction filters

direct orthogonal signal correction(dosc) and savitzky-golay filters (sgf) were applied as preprocessing methods on the original and first derivative absorbance data. principle component regression (pcr), partial least squares (pls) and iterative target transformation factor analysis (ittfa), were used in spectrophotometric simultaneous determination of heavy divalent metal ions, lead, zinc,mer...

full text

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

Spectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares

A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...

full text

Simultaneous Spectrophotometric Determination of Mycophenolate Mofetil and Its Active Metabolite in Human Plasma Using Chemometrics Methods

A spectrophotometric method for selective complexation reaction and simultaneous determination of mycophenolate mofetil (MPM), and mycophenolic acid (MPA) using three multivariate chemometric methods, i.e. partial least squares regression, principal component regression and principal component artificial neural networks, is proposed. The method is based on the complexation reaction of ...

full text

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

comparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods

هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 26  issue 2

pages  41- 51

publication date 2007-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023