Serviceability Response of Rehabilitated Unbonded Post-tensioned Indeterminate I-Beams Consisting UHSSCC
Authors
Abstract:
The ultra-high strength self-compacting concrete, UHSSCC is the new generation type of concrete with a compressive strength higher than 80MPa. The application of this type of concrete on the serviceability state in CFRP strengthened unbonded post-tensioned indeterminate I-beam is monitored and the results are compared theoretically using different standards. For this aim, full scale I-beam of 9m length was cast, by UHSSCC. During the beam service load test, the stress and strain of materials, and also deflection and crack widths were monitored at different locations using different types of sensors. Based on the experimental measurements and observations, the beam serviceability response was compared theoretically by different methods. As the considerations prepared in the standards do not cover strengthening of such members with unbonded tendons, and also no trace of deflection prediction for such continuous member, one can find in the open literature. It is therefore, this investigation was planned. A comparison between theoretical and monitored results was performed for serviceability response and it was found that although, the stress of materials are well within the standards limitations for crack widths of 0.1 and 0.2 mm of bonded tendon, but the full service load is reached at a higher load, while the flexural crack, experience a width of 0.3 mm. It is also apparent that the loads corresponding to the conventional suggested deflection limits will cause to exceed serviceability state of strengthened unbonded beam, and new limitations are introduced for crack widths of 0.1, 0.2 and 0.3 mm to predict service deflection of beams.
similar resources
Ultimate Unbonded Tendon Stress in CFRP Strengthened Post-Tensioned Indeterminate I-Beams Cast with HSCs
Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the analysis of the stress increment of unbonded tendons is monitored in the loading process. Since self-compacting concrete (SCC) is a suitable innovation,, understanding the implementation of this type of concrete on the ultimate unbonded tendon stress is criti...
full textUltimate Tendon Stress in CFRP Strengthened Unbounded HSC Post-Tensioned Continuous I-Beams
The use of unbounded tendons is common in prestressed concrete structures and evaluation of the stress increase in unbonded tendons at ultimate flexural strength of such structure has posed a great challenge over the years. Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the monitoring of the stress increment ...
full textNonlinear Models of Reinforced and Post-tensioned Concrete Beams
Commercial finite element software generally includes dedicated numerical models for the nonlinear response of concrete under loading. These models usually include a smeared crack analogy to account for the relatively poor tensile strength of concrete, a plasticity algorithm to facilitate concrete crushing in compression regions and a method of specifying the amount, the distribution and the or...
full textUnbonded Post Tensioned Concrete Slabs in Fire – Part II – Modelling Tendon Response and the Consequences of Localized Heating
This is Part II of a two part paper dealing with the current state of knowledge of the fire-safe structural design and construction of unbonded post-tensioned (UPT) flat plate concrete structures. Part I provided detailed results of nineteen transient high temperature stress relaxation tests on restrained UPT tendons of realistic length and parabolic longitudinal profiles. Experimentation ident...
full textUnbonded Post Tensioned Concrete in Fire: A Review of Data from Furnace Tests and Real Fires
The fire-safe design of concrete structures which incorporate post-tensioned prestressing tendons has recently been the subject of debate within the structural engineering community, particularly when unbonded post-tensioned (UPT) prestressing tendons are used. Despite several studies aimed at furthering our understanding of the response of UPT concrete structures in fire, many aspects of their...
full textExploratory experimental investigations on post - tensioned structural glass beams
The mechanical response of post-tensioned glass beams is explored in this paper. This is done through bending experiments on post-tensioned glass beam specimens with either mechanically anchored or adhesively bonded steel tendons by which a beneficial pre-stress is inflicted on the glass beams. In addition, reference beams with identical geometry but without tendons are tested. From the results...
full textMy Resources
Journal title
volume 3 issue 2
pages 16- 29
publication date 2015-08-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023