Removal of High Concentrations of Phenol in Dual Chamber Microbial Fuel Cell

Authors

  • Ghalenoei, Morteza MSc in Environmental Health Engineering, Faculty of Health, Mazandaran University of Medical Sciences, Sari, Iran
  • Dianati tilaki, Ramazan ali Associate Professor, Department of Environmental Health, Faculty of Health, Mazandaran University of Medical Sciences, Sari, Iran
  • Eslamifar, Masoumeh PhD Student in Microbiology, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran
Abstract:

Background and purpose: Microbial fuel cell is one of the sustainable development technologies that can be used simultaneously for removal of many pollutants and generate electricity. The aim of this study was to determine the removal rate of high concentrations of phenol in a microbial fuel cell. Materials and methods: A dual chamber microbial fuel cell having Nafion proton exchange membrane and carbon cloth as anode and cathode was fabricated and operated in batch mode in incubator at 30°C for 12 weeks. Anode was put in anaerobic chamber containing minimum growth medium and phenol (50-1000ppm) was added as the sole carbon source. Phenol degrading bacterial seed that was supplied by wastewater treatment plant of Tehran Petroleum Refinery was adapted to phenol and used in anaerobic anode chamber. Cathode was put in aerobic chamber containing phosphate buffer. Concentration of remained phenol in different times was analyzed by HPLC method. Results: Maximum amount of phenol degradation occurred in the first 24h of each run. Phenol concentrations up to 800 ppm were completely removed during 96 h, but time to complete removal of 1000 ppm phenol was 120h. Conclusion: By using sludge from wastewater treatment plant of oil refinery adapted to phenol in a microbial fuel cell, it is possible to remove 1000 ppm phenol.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Performance of a Dual Chamber Microbial Fuel Cell using Sodium Chloride as Catholyte

Microbial fuel cell represents an emerging technology to attain electrical energy from wastewater. There are several alternative methods available for wastewater treatment; Microbial fuel cell is one of them, which generates green energy from wastewater for making a contribution to renewable sources of energy. This study states the performance of microbial fuel cell with different parameters i....

full text

Performance of a Dual Chamber Microbial Fuel Cell using Sodium Chloride as Catholyte

Microbial fuel cell represents an emerging technology to attain electrical energy from wastewater. There are several alternative methods available for wastewater treatment; Microbial fuel cell is one of them, which generates green energy from wastewater for making a contribution to renewable sources of energy. This study states the performance of microbial fuel cell with different parameters i....

full text

Simultaneous electricity generation and sulfide removal via a dual chamber microbial fuel cell

 Transfer of produced electrons to anode is one of the main parts in MFCs.  Some MFCs needs artificial electron acceptors in their aerobic cathode compartment.  Cyclic voltammetry was used to study of anodic electrochemistry analysis.  Hexacyanoferrate was used as cathodic solution in different concentrations.  Maximum generated voltage and power density were 988.9145 mV, 346.746 mW.m, res...

full text

Application of dual chamber microbial fuel cell with aeration cathode for bioelectricity generation and simultaneous industrial wastewater treatment

Background and Objective: Microbial fuel cell (MFC) is a new green technology that uses the catabolic ability of microorganisms to produce bioenergy while simultaneously removing organic matter and other wastewater contaminants. Electrode material is one of the factors affecting the performance of microbial fuel cells. The aim of this study was to investigate the performance of microbial fuel c...

full text

Microbial fuel cell performance with a pressurized cathode chamber.

Microbial fuel cell (MFC) power densities are often constrained by the oxygen reduction reaction rate on the cathode electrode. One important factor for this is the normally low solubility of oxygen in the aqueous cathode solution, which creates mass transport limitation and hinders oxygen reduction at the electrocatalyst (platinum, Pt). Here, we increased the air pressure in the cathode chambe...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 30  issue 185

pages  149- 153

publication date 2020-05

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023