Relationship between Electrically Evoked Compound Action Potential Thresholds and Auditory, Language, and Speech Progress after Cochlear Implant Surgery

Authors

  • Masoud Motesadi Zarandi Department of Ear, Nose and Throat, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
  • Navid Nourizadeh Sinus and Surgical Endoscopic Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Sadegh Jafarzadeh Department of Audiology, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.
Abstract:

Introduction: Electrically evoked compound action potential (ECAP) is an objective auditory response that can be used in the programing of cochlear implants. The aims of this study were to monitor ECAP thresholds and auditory, language and speech progress for 6 months after cochlear implant surgery and to evaluate any relationship between them.   Materials and Methods: Ten children with a mean age of 4.2 (±0.6) years and bilateral congenital and profound sensorineural hearing loss underwent cochlear implant surgery and post-operation auditory and speech training. The auditory, language, and speech abilities (Newsha level) and ECAP thresholds (for apical, medial and basal region of cochlea) were evaluated 1, 3 and 6 months after surgery.                                                                                                                            Results: ECAP threshold showed no significant improvement in any of the evaluated areas in the 6 months after surgery (P>0.05); however, the Newsha level improved for all patients (P=0.00).   Conclusion: There was no relationship between ECAP thresholds and auditory, language, and speech abilities (Newsha level) in the first 6 months after surgery. ECAP thresholds may be a poor indicator of improvement in auditory, language, and speech abilities, and depend on many factors.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Comparison of electrically evoked whole-nerve action potential and electrically evoked auditory brainstem response thresholds in nucleus CI24R cochlear implant recipients.

In this study, differences between electrically evoked whole-nerve action potential (EAP) and electrically evoked auditory brainstem response (EABR) measurements within Nucleus CI24R cochlear implant recipients were evaluated. Precurved modiolus-hugging internal electrode arrays, such as the CI24R, are designed to provide more direct stimulation of neural elements of the modiolus. If the electr...

full text

Effects of long-term use of a cochlear implant on the electrically evoked compound action potential.

BACKGROUND Since the early 1990s, it has been possible to measure electrically evoked compound action potentials (ECAPs) from Nucleus cochlear implant users. Recording the ECAP does not require active participation by the subject, and the recordings are not adversely affected by attention or sleep, making this response an ideal tool for monitoring long-term changes. Previous research from our l...

full text

Impedance and Electrically Evoked Compound Action Potential (ECAP) Drop within 24 Hours after Cochlear Implantation

Previous animal study revealed that post-implantation electrical detection levels significantly declined within days. The impact of cochlear implant (CI) insertion on human auditory pathway in terms of impedance and electrically evoked compound action potential (ECAP) variation within hours after surgery remains unclear, since at this time frequency mapping can only commence weeks after implant...

full text

Influence of evoked compound action potential on speech perception in cochlear implant users.

UNLABELLED Electrically Evoked Compound Action Potential is a measure of synchronous cochlear nerve fibers activity elicited by electrical stimulation of the cochlear implant. The electrophysiological nerve responses may contribute to explain the variability in individual performance of cochlear implant recipients. AIM To compare speech perception tests performances of cochlear implant users ...

full text

Influence of Evoked Compound Action Potential on Speech Perception in Cochlear Implant Users Summary

El ectrically Evoked Compound Action Potential is a measure of synchronous cochlear nerve fibers activity elicited by electrical stimulation of the cochlear implant. The electrophysiological nerve responses may contribute to explain the variability in individual performance of cochlear implant recipients. Aim: To compare speech perception tests' performances of cochlear implant users according ...

full text

Electrically evoked auditory brainstem responses in cochlear implant patients.

Electrically evoked auditory brainstem responses (EABR) were recorded in completely deaf patients implanted with Ineraid multichannel cochlear implants. Clear and reproducible EABR were obtained from all patients. Parametric differences with auditory brainstem responses (ABR) were demonstrated and can be explained by the different natures of both types of stimulations (electric versus acoustic)...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 30  issue 4

pages  185- 188

publication date 2018-07-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023