Reactive and Active Power Control of Grid WECS Based on DFIG and Energy Storage System under both Balanced and Unbalanced Grid Conditions

Authors

  • Neda Azizi Department of Electrical Engineering, Faculty of Engineering, Razi University, Kermanshah, Iran
Abstract:

This paper focuses on improving the active and reactive power control of Wind Energy Conversion System (WECS) by employing the Battery Energy Storage System (BESS) and controlling the frequency and voltage regulation instantaneously. The proposed power control scheme is composed of two control loops so that they are implemented and designed for active power control and controlling the reactive power, respectively, which both are equipped with PI type controllers. In addition, two control loops were utilized to control the frequency and voltage on the rotor side converter under balance and unbalance grid conditions. In this paper, the presented control strategy optimally tuned all the parameters of controllers at the same time by utilizing a mixed integer nonlinear optimization programming and solved by the ICA algorithm. Moreover, in order to demonstrate the effectiveness of the proposed strategy, non-linear time domain simulations were carried out in MATLAB software. The obtained simulation results verified that the proposed control scheme efficiently utilize BESS to control the active and reactive power control and confirm the effectiveness of the proposed strategy under the balanced and unbalanced grid conditions.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition

This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...

full text

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

full text

A Novel Control Scheme for DFIG-based Wind Energy Systems under Unbalanced Grid Conditions

This paper presents an analysis and a novel control scheme for a doubly-fed induction generator (DFIG) based wind energy generation under unbalanced grid conditions. The control objectives are: (i) to limit the rotor currents, (ii) to suppress ripples in the torque and (iii) to suppress the dc-link voltage fluctuation through converter controls. Negative sequence compensation techniques by one ...

full text

Model Predictive Control of a BCDFIG With Active and Reactive Power Control Capability for Grid-Connected Applications

Recently, Brushless Cascaded Doubly Fed Induction Generator (BCDFIG) has been considered as an attractive choice for grid-connected applications due to its high controllability and reliability. In this paper, a Finite Control Set Model Predictive Control (FCS-MPC) method with active and reactive power control capability in grid-connected mode is proposed for controlling the BCDFIG in a way that...

full text

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

full text

Active Power Filtering Using the ZDPC Method under Unbalanced and Distorted Grid Voltage Conditions

1 Power Electronics and Industrial Control Laboratory, University of Sétif1, Sétif 19000, Algeria 2 Department of Electronics, University of Msila, Msila 28000, Algeria; E-Mail: [email protected] 3 Department of Electronics, University of Sétif1, Sétif 19000, Algeria 4 Department of Electrotechnics, University of Sétif1, Sétif 19000, Algeria; E-Mail: [email protected] 5 Department of Electr...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 4  issue 4

pages  31- 38

publication date 2019-06-25

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023