PVC based 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane electrode for Cerium (III) ions

Authors

  • Arezoo Ghaemi Department of Chemistry, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
  • Fariba Mehranfar Department of Chemistry, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
  • Haman Tavakkoli Department of Chemistry, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
Abstract:

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two months without any considerable divergence in its potential. The proposed sensor revealed high selectivity toward Ce3+ ion with respect to some alkali, alkaline earth and transition metal cations. It could be used in a wide pH range of 2.0-11.0. The sensor was successfully used as an indicator electrode in potentiometric titration of Ce3+ ion with ethylenediaminetetraacetic acid (EDTA) and sodium iodide (NaI) solutions, and in determination of Ce (III) concentration in real samples.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Charge-transfer triiodide ion-selective electrode based on 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane.

A new PVC membrane electrode for the triiodide ion based on a charge-transfer complex of iodine with 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as a membrane carrier was prepared. The electrode exhibits a Nernstian response for triiodide ions over a wide concentration range (1.0 x 10(-1)-1.0 x 10(-5) M) with a slope of 59.3 +/- 0.9 mV decade(-1) and a detection limit of 6.3 x 10...

full text

Jgp_201711777 413..416

By tracking conformational transitions of individual ion channel proteins, single-channel recordings allow the observer to deduce gating mechanisms, as well as estimate rate constants of microscopic gating steps. For most ion channels, gating mechanisms are complex, comprising multiple stable open (O) and closed (C) conformations among which conformational transitions may follow a network of po...

full text

Dmd048009 406..413

The pregnane X receptor (PXR) has been postulated to play a role in the metabolism of a-tocopherol owing to the up-regulation of hepatic cytochrome P450 (P450) 3A in human cell lines and murine models after a-tocopherol treatment. However, in vivo studies confirming the role of PXR in a-tocopherol metabolism in humans presents significant difficulties and has not been performed. PXR-humanized (...

full text

Jgp_201711777 413..416

By tracking conformational transitions of individual ion channel proteins, single-channel recordings allow the observer to deduce gating mechanisms, as well as estimate rate constants of microscopic gating steps. For most ion channels, gating mechanisms are complex, comprising multiple stable open (O) and closed (C) conformations among which conformational transitions may follow a network of po...

full text

406 - 413 Yan Li.pmd

In the present study, a total of 137 blood samples were collected from cattle and water buffaloes in central region of Vietnam and tested using nested polymerase chain reaction (nPCR), enzyme-linked immunosorbent assay (ELISA) and indirect fluorescent antibody test (IFAT) to determine the molecular and serological prevalence of Babesia bovis and Babesia bigemina. In cattle, the prevalence of B....

full text

A novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples

A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 8  issue 2

pages  43- 54

publication date 2018-04-01

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023