Protective and dosimeter design of the stationary and mobile model truck inspection system with electron linear accelerator radiation source

Authors

Abstract:

In this work, calculations of leaked dose from vehicle inspection area, the absorbed dose by driver and operator, and the required concrete thickness for shielding the inspection area are presented using the Monte Carlo code MCNPX2.6. The X-ray source of the present vehicle inspection system is a LinatronMi6 accelerator, end of which has only been simulated in this study (the electron beam colliding with the anode, anode, filters, and the paralyzers in the path of the generated photons). In this study, first the optimum electron beam current with the energy of 6 MeV in the LinatronMi6 is calculated in such a way that a dose rate of 8 Gy/min in 1 meter away from the accelerator is obtained. Then, the absorbed dose rate by driver is calculated in different vehicle speeds: 0.2m/s, 1m/s, 2m/s, 3m/s and 4m/s. Also, three different materials - air, water and iron for cargo have been considered and for each material, the absorbed dose by driver is calculated separately. Simulation results show that the absorbed dose by the driver for the lower speeds of vehicle and higher atomic numbers and densities of material is higher. Therefore, by assuming 2 m/s as the vehicle speed and iron as the cargo material (worst case scenario), the required lead and steal thickness for shielding the operator room is calculated to be 3mm steal and 10.5 mm lead. At the end of this study, the required thickness of concrete for the inspection area walls is calculated. According to the simulation results, 52 cm concrete in the entrance gate and 40 cm in other parts are sufficient to keep the leaked dose from the wall lower than 5μSv/h.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

the evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology

abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...

15 صفحه اول

the innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran

آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...

15 صفحه اول

simulation and design of electronic processing circuit for restaurants e-procurement system

the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...

15 صفحه اول

Design and Optimization of the Target in Electron Linear Accelerator

The target in electron linear accelerator plays an important role in the production of photon. Different materials and thickness of target have influence on dose rate. For 6MeV electron beam, this study gives the thickness of target for several materials in which the dose rate can be higher and drain electron can be lower. Then a X-ray target had been designed for 6MeV electron linac by FLUKA s...

full text

Radiation survey around a Liac mobile electron linear accelerator for intraoperative radiation therapy

The aim of this study was to perform a detailed analysis of the air kerma values around a Liac mobile linear accelerator working in a conventional operating room (OR) for IORT. The Liac delivers electron beams at 4, 6, 8 and 10 MeV. A radiation survey to determine photon leakage and scatter consisted of air kerma measurements on a spherical surface of 1.5 m radius, centered on the titanium exit...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 6  issue 4

pages  11- 18

publication date 2018-09

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023