Pharmaceutical Wastewater Chemical Oxygen Demand Reduction: Electro-Fenton, UV-enhanced Electro-Fenton and Activated Sludge

Authors

  • Reza Davarnejad Department of Chemical Engineering, Faculty of Engineering, Arak University, Arak, Iran
  • Rezvan Behfar Department of Chemical Engineering, Faculty of Engineering, Arak University, Arak, Iran
  • Rouhollah Heydari Research Center for Environmental Determinants of Health, Kermanshah University of Medical Sciences, Kermanshah, Iran
Abstract:

In this study, Chemical Oxygen Demand (COD) from a pharmaceutical wastewater (PhW) was reduced by several techniques such as electro-Fenton (EF), photo electro-Fenton (PEF) and activated sludge (AS) processes and the obtained data were compared with each other. The effects of several parameters such as pH, current density, H2O2/Fe2+ molar ratio, volume ratio of H2O2/PhW, reaction time and UVA light were studied on the COD reduction through the EF and PEF processes. The Box-Behnken Design (BBD) under Response Surface Methodology (RSM) was applied to design and then optimize these processes. The optimal conditions for 87% of COD removal through the EF process were at pH of 3.27, current density of 57 mA/cm2, H2O2/Fe2+ molar ratio of 3.5, volume ratio of H2O2/PhW of 1.34 ml/l and reaction time of 56.32 min while the optimal conditions for 91.6% of COD removal through PEF process were at pH of 3.5, current density of 57.5 mA/cm2, H2O2/Fe2+ molar ratio of 3.81, volume ratio of H2O2/PhW of 1.5 ml/l, reaction time of 10.12 min and 6 W UVA light while 77.70% of COD removal was obtained by  the AS process with residence time of 1020 min. According to the kinetic study, the second order reaction (with high R2 data) could properly model the EF and PEF processes.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Ibuprofen Removal from a Pharmaceutical Wastewater using Electro-Fenton Process: An Efficient Technique (RESEARCH NOTE)

The aim of this research was to evaluate the effective parameters such as pH, current density (mA/cm2), H2O2/Fe2+ molar ratio, volume ratio of H2O2 to pharmaceutical wastewater (PhW) (ml/l) and reaction time (min) on the electro-Fenton process for the ibuprofen (as a pharmaceutical waste in water) removal. Since a synthetic wastewater with the same concentration of ibuprofen in a real pharmaceu...

full text

Investigating the efficiency of chemical coagulation/Electro-Fenton process in the removal of organic matter from pharmaceutical industry wastewater

Background and Objective: Wastewater from pharmaceutical industry has high chemical oxygen demand as a result of the presence of organic drugs and antibiotics. In order to meet the environmental requirements, several treatment methods like chemical and electrochemical methods have been widely applied due to their high ability to remove organic compounds from pharmaceutical wastewater. Therefore...

full text

Reduction of COD in wastewater from an organized tannery industrial region by Electro-Fenton process.

Advanced oxidation processes (AOPs) have led the way in the treatment of aqueous waste and are rapidly becoming the chosen technology for many applications. In this paper, COD reduction potential of leather tanning industry wastewaters by Electro-Fenton (EF) oxidation, as one of the AOPs, was experimentally evaluated. The wastewater sample was taken from an outlet of an equalization basin in a ...

full text

Landfill Leachate Treatment through Electro-Fenton Oxidation

Advanced Oxidation Processes (AOPs) have been employed to degrade biorefractory organic matters. This study investigates the combination of classical Fenton reaction with electrochemical oxidation, the electro-Fenton process, for the treatment of semi aerobic landfill leachate, collected from Pulau Burung Landfill Site (PBLS), Penang, Malaysia. The investigation has been carried out in batch re...

full text

Landfill Leachate Treatment through Electro-Fenton Oxidation

Advanced Oxidation Processes (AOPs) have been employed to degrade biorefractory organic matters. This study investigates the combination of classical Fenton reaction with electrochemical oxidation, the electro-Fenton process, for the treatment of semi aerobic landfill leachate, collected from Pulau Burung Landfill Site (PBLS), Penang, Malaysia. The investigation has been carried out in batch re...

full text

laundry wastewater treatment using electrocoagulation/flotation and electro-fenton processes

several laundry houses throughout tehran consume a large amount of water each day and discharge the resulting wastewater into septic tanks or municipal sewage system without any suitable pretreatment. this would result in severe contamination and other serious environmental issues. in the present study, performance of electrocoagulation/flotation process with aluminum and iron electrodes is com...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 32  issue 12

pages  1710- 1715

publication date 2019-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023