Performance Comparison of Two Different Branded Blood Collection Tubes Used in Biochemistry Laboratory
Authors
Abstract:
Background and Aims: Blood collection tubes (BCT) with gel separators are diagnostic devices that can affect all laboratory processes. In this study, the aim was to compare the performance of a new brand of BCT with the sample tubes that are well-known and widely used in the market. Materials and Methods: Blood samples were taken from 50 healthy volunteers to two brands of BCTs (KWS and BD Vacutainer SST II Advance) by providing standard conditions. The nine most requested test parameters were determined and analyzed simultaneously. The results were analyzed using the SPSS 21 software. Results: There was no significant difference in the results of most tests of the new brand tubes compared to the Becton-Dickinson brand tube, and the bias calculated for the tests except calcium and potassium was detected to be lower than the desirable bias. Conclusion: It was determined that the test parameters analyzed in both tubes were in statistical agreement. The percentage of bias value of calcium and potassium tests in KWS branded tubes is higher than the desired value. In addition, constant and proportional errors were determined for the calcium test. These test parameters should be analyzed in larger patient groups. Therefore, KWS tubes can be accepted for routine laboratory operations.
similar resources
comparison of the amount of debris extruded apically in two rotary techniques: flexmaster and m2
چکیده ندارد.
15 صفحه اولPerformance of chemically modified plastic blood collection tubes.
OBJECTIVE The objective of this study was to compare newly-modified and aged chemoPET tubes, which contain no problematic surfactants, with commercially available serum blood collection tubes (BCTs) for use in analysis of cortisol, total triiodothyronine (TT3), total thyroxine (TT4), and routine clinical chemistry analytes in serum from apparently healthy volunteers and pooled quality control (...
full textImplementation of biological variation-based analytical performance specifications in the laboratory: Stringent evaluation of Improvacutor blood collection tubes
Recently, because the quality of laboratory analyses has increased along with the need for quality improvement, several external quality control bodies have adapted performance specifications using the Desirable Biological Variation Database, termed "Ricos goals"; these criteria are more stringent than those presented in CLIA 88. In this study, we aimed to validate newly introduced serum separa...
full textthe role of application of dynamic assessment approach in improvement of iranian efl writing performance at different language proficiency levels
the present study sought to investigate the role of dynamic assessment (da) in improvement of iranian efl writing performance at different language proficiency levels. to this end, after conducting the quick placement test, 60 iranian efl learners were assigned to two groups with different language proficiency levels. in both groups each participant wrote two compositions, one before and one af...
Comparison of Two Different Blood Sample Tubes for Platelet Function Analysis with the Multiplate® System.
BACKGROUND: For whole blood aggregation on the Multiplate® system, the use of thrombin inhibitor as anticoagulant is recommended. So far sample tubes containing liquid lepirudin were provided (Dynabyte, Munich, Germany). They are not sterile and have to be stored refrigerated. For better handling now also sterile tubes with dried hirudin, storable at room temperature, are also provided (Dynabyt...
full textEffect of blood collection tubes on total triiodothyronine and other laboratory assays.
BACKGROUND Increased total triiodothyronine (TT(3)) assay results in apparently euthyroid patients triggered an investigation of the effect of blood collection tubes on serum TT(3) and other laboratory assays. METHODS We examined potential assay interference for three types of tubes: plastic Greiner Bio-One Vacuette; glass Becton Dickinson (BD) Vacutainer; and plastic BD Vacutainer SST tubes....
full textMy Resources
Journal title
volume 9 issue 3
pages 209- 217
publication date 2022-08
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023