Operation of Stand Alone PV Generating System for Supplying Unbalanced AC Loads

Authors

  • G. B. Gharehpetian
  • M. Abedi
  • R. Noroozian
  • S. H. Hosseini
Abstract:

This paper describes a DC isolated network which is fed with Distributed Generation (DG) from photovoltaic (PV) renewable sources for supplying unbalanced AC loads. The battery energy storage bank has been connected to the DC network via DC/DC converter to control the voltage of the network and optimize the operation of the PV generation units. The PV arrays are connected to the DC network via its own DC/DC converter to ensure the required power flow. The unbalanced AC loads are connected to the DC network via its own DC/AC converter. This paper proposes a novel control strategy for storage converter which has a DC voltage droop regulator. Also a novel control system based on Park rotating frame has been proposed for DC/AC converters. In this paper, the proposed operation method is demonstrated by simulation of power transfer between PV arrays, unbalanced AC loads and battery unit. The simulation results based on PSCAD/EMTDC software show that DC isolated distribution system including PV generation systems can provide the high power quality to supplying unbalanced AC loads.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Optimal Configuration for Design of Stand-Alone PV System

This paper presents a design for a stand-alone photovoltaic (PV) system to provide the required electricity for a single residential household in rural area in Jordan. The complete design steps for the suggested household loads are carried out. Site radiation data and the electrical load data of a typical household in the considered site are taken into account during the design steps. The relia...

full text

A New Dead Time Compensation method for Stand - alone Inverter under Unbalanced Loads

phase stand-alone inverter is caused by unbalanced load and a dead time distorts inverter output voltage more unsymmetrically. When the inverter supplies unbalanced load, three phase output voltages include unbalanced odd harmonics but dq-axis voltages at synchronous reference frame have even harmonics with different magnitude each other. In this paper, a new compensation method is proposed to ...

full text

An application of vector based swarm optimization for designing MPPT controller of a stand-alone PV System

In this paper, the Vector Based Swarm Optimization method is used for designing an optimal controller for the maximum power point tracker of a stand-alone PV System. The proposed algorithm is executed on vectors in a multi-dimension vector space. These vectors by appropriated orientation converge to a global optimum while the algorithm runs. The Remarkable point of the VBSO algorithm is how us...

full text

Power Quality Improvement in a Speed Sensorless Stand-alone DFIG Feeding General Unbalanced Non-linear Loads

This paper reports the performance of a speed sensorless stand-alone Variable Speed Constant Frequency (VSCF) Doubly Fed Induction Generator (DFIG) capable of supplying all types of loads. The proposed method maintains the Total Harmonic Distortion (THD) of the machine current and the load voltage within acceptable limits. In contrast to previously proposed methods, in this paper, the stator si...

full text

Power System Harmonics Study for Unbalanced Microgrid System with PV Sources and Nonlinear Loads

Harmonics distortion is a crucial problem in microgrid. Harmonic sources can be categorized as two main factors: renewable energy integration and nonlinear loads. Both factors are investigated in this paper. For renewbale energy, photovoltaic (PV) power is one of the most effective solutions for energy crisis and it is showing great potential for serving customers in microgrid. A threephase PV ...

full text

Direct Flux Control for Stand-Alone Operation

In this paper, a novel voltage control strategy of stand-alone operation brushless doubly 9 fed induction generator for variable speed constant frequency wind energy conversion systems 10 was presented and discussed particularly. Based on the model of the generator power system, the 11 proposed direct flux control strategy employs a nonlinear reduced-order generalized integrator 12 based resona...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 3  issue 3

pages  98- 115

publication date 2007-07

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023