Abstract:

Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty µl of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1mm×30mm, 3.5 micron). The mode of mass spectrometry was selected-ion monitoring (SIM). Results: Standard curve was linear (r= 0.998) over the concentration range of 0.1–100.0 ng/ml and showed a suitable accuracy and precision. The limit of detection (LOD) was 0.05ng/ml. Conclusion: The method is quick, easy, very steady and precise for the partition, assignment and evaluation of methotrexate in human plasma.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

method validation of methotrexate in human plasma by lc-ms technique in patients with brain tumor.

background and aims: a selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. methods: methotrexate was extracted from plasma with acetonitrile. the mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). twenty µl of sample was chromatographically an...

full text

Method validation of clonidine hydrochloride in human plasma by LC-MS technique

A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...

full text

Method validation of clonidine hydrochloride in human plasma by LC-MS technique

Introduction Clonidine (Fig. 1), an imidazoline derivative, is a centrally acting hypotensive agent but its use is being explored in a number of other indications such as anesthesia and the management of opiate with drawl (1). Clonidine belongs to a class of drugs called central alpha-adrenergic agonists. Clonidine has been in clinical use for over 40 years, which is used to treat hypertensive ...

full text

Validation of a selective method for determination of paroxetine in human plasma by LC-MS/MS.

PURPOSE A sensitive, robust, and selective liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) was developed and validated for paroxetine quantification in human EDTA plasma. METHODS Sample preparation was based on liquid-liquid extraction using a mixture of ethyl acetate/hexane (50/50; v/v) to extract the drug and internal standard from plasma. Chromatography was performed on ...

full text

pharmacokinetics and bioequivalence of methotrexate in human plasma studied by liquid chromatography-mass spectrometry (lc-ms)

background methotrexate is a folic acid antagonist that has been in clinical use for five decades. its use in patients with brain tumors is primarily confined to primary central nervous system lymphoma (pcnsl), in which it is the cornerstone of chemotherapy. objectives a selective and sensitive high-performance liquid chromatography-electrospray ionization-mass spectrometry method was developed...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 3  issue 2

pages  162- 171

publication date 2016-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023