Measurements of output factors using different ionization chambers and build up caps

author

Abstract:

Background: The aim of this work was to study the output factors for Linac using different ionization chambers and build up caps. Materials and Methods: Output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 MV photon beams from a Varian Clinac 2100C accelerator were measured. The measurements in air were performed using Compact Cylindrical and Farmer type ionization chamber fitted with acrylic and brass build up caps. All measurements were taken with the detector set with its central axis perpendicular to the beam central axis and isocentrically positioned at the reference depth in empty water phantom. Results and Discussion: It was observed that out put factors increased with field size for both 6 and 15 MV photon beams. The increase in output factor is less prominent for brass build-up caps than acrylic build up caps. Up to 1.53% and 0.97 % difference were observed between 6 and 15 MV energies for acrylic and brass build up caps respectively. For acrylic build up cap, no significant difference was found for both ionization chambers. However, measurements for brass and acrylic build up caps with same ion chamber differ by up to 4.4 % for 15 MV energy. Conclusions: The measurement of output factors Shwith cylindrical build-up cap made of high Z material distorts Shand should be avoided. The use of buildup caps with Zeff close to that of water such as acrylic is a good choice. Ionization chamber is the best choice for Sh measurements for large field sizes. Iran. J. Radiat. Res., 2012 10(2): 95‐98

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

measurements of output factors using different ionization chambers and build up caps

background: the aim of this work was to study the output factors for linac using different ionization chambers and build up caps. materials and methods: output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 mv photon beams from a varian clinac 2100c accelerator were measured. the measurements in air were performed using compact cyli...

full text

Interpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions

Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...

full text

comparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods

هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...

15 صفحه اول

SU-E-T-176: Improved Collimator Scattering Factor (Sc) Measurements for Small Fields Using Build-Up Caps in Robotic Radiosurgery.

PURPOSE The Monte Carlo calculation algorithm in the MultiPlan (Accuray, Palo Alto, CA) treatment planning system used for CyberKnife (Accuray) robotic radiosurgery requires in-air measurements. In this study, results were compared for the impact of build-up caps using a diode detector for small field in-air measurements. METHODS Two acrylic caps custom-made for the SFD diode detector (IBA, G...

full text

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

LET Monitoring Using Liquid Ionization Chambers

Relative biological effectiveness (RBE) is an important quantity in planning particle beam cancer therapy. In general, the RBE describes the biological effectiveness of a given primary beam with respect to a reference photon irradiation. RBE varies not only for different primary beams but also with depth in the target for a given beam modality. It is not a quantity that easily lends itself to m...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 10  issue None

pages  95- 98

publication date 2012-09

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023