Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging
Authors
Abstract:
Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the mechanical and anatomical axis is important. The aim of this study was to evaluate the value of posterior tibial slope in medial and lateral compartments of tibial plateau and to assess the relationship among the slope with age, gender and other variables of tibial plateau surface. Materials and methods: This descriptive study was conducted on 132 healthy knees (80 males and 52 females) with a mean age of 38.26±11.45 (20-60 years) at a medical center in Mashhad, Iran. All patients required to MRI admitted for knee pain with uncertain clinical history and physical examination that were reported healthy at knee examination were enrolled in the study. Results: The mean posterior tibial slope was 7.78±2.48 degrees in the medial compartment and 6.85±2.24 degrees in lateral compartment. No significant correlation was found between age and gender with posterior tibial slope (P≥0.05), but there was significant relationship among PTS with mediolateral width, plateau area and medial plateau. Conclusions: Comparison of different studies revealed that the PTS value in our study is different from other communities, which genetic and racial factors can be involved in these differences. The results of our study are useful to PTS reconstruction in surgeries.
similar resources
Magnetic resonance imaging of feline eye
The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...
full textFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
full textTotal knee arthroplasty and posterior tibial slope
Total Knee Arthroplasty (TKA) has been considered as a standard procedure for intractable pain in the end-stage degenerative arthritis of the knee and maintaining range of motion (ROM) to facilitate the ability to perform daily living activities. 1 Factors that have been associated with the change in ROM after TKA include preoperative ROM, implant design, patient characteristics, posterior femo...
full textMy Resources
Journal title
volume 5 issue 6
pages 435- 439
publication date 2017-11-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023