Measurement and Modeling of Mean Ionic Activity Coefficient in Aqueous Solution Containing NaNO3 and Poly Ethylene Glycol

Authors

  • Farzaneh Feyzi Chemical Engineering Department, Iran University of Science and Technology, Tehran, I.R. IRAN
  • Parinaz Alimardani Chemical Engineering Department, Iran University of Science and Technology, Tehran, I.R. IRAN
  • Sara Kazemi Sabzvar Chemical Engineering Department, Iran University of Science and Technology, Tehran, I.R. IRAN
  • Siamak Modarresi Chemical Engineering Department, Iran University of Science and Technology, Tehran, I.R. IRAN
Abstract:

Potentiometric investigation on {H2O+NaNO3+PEG1500} mixtures were made at T=308.15K, using electrochemical cells with two ion-selective electrodes, (Na+ glass) as the cation ion-selective electrode against (NO3- solvent-polymer PVC) as the anion ion-selective electrode. The mean ionic activity coefficients of NaNO3 were measured at different concentrations of  NaNO3 and PEG. Maximum concentration of electrolyte and PEG were 1 mol/kg and 0.12 mol/kg, respectively. The experimental data was modeled by utilizing the modified Pitzer equation and the activity coefficient ratio of PEG was evaluated by using Maxwell’s cross differential relation. 

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

measurement and modeling of mean ionic activity coefficient in aqueous solution containing nano3 and poly ethylene glycol

potentiometric investigation on {h2o+nano3+peg1500} mixtures were made at t=308.15k, using electrochemical cells with two ion-selective electrodes, (na+ glass) as the cation ion-selective electrode against (no3- solvent-polymer pvc) as the anion ion-selective electrode. the mean ionic activity coefficients of nano3 were measured at different concentrations of  nano3 and peg. maximum concentrati...

full text

Measurement of poly(ethylene glycol) by cell-based anti-poly(ethylene glycol) ELISA.

Poly(ethylene glycol) (PEG) is increasingly used in clinical and experimental medicine. However, quantification of PEG and PEGylated small molecules remains laborious and unsatisfactory. In this report, we stably expressed a functional anti-PEG antibody on the surface of BALB 3T3 cells (3T3/alphaPEG cells) to develop a competitive enzyme-linked immunosorbent assay (ELISA) for PEG quantification...

full text

Degradative properties and cytocompatibility of a mixed-mode hydrogel containing oligo[poly(ethylene glycol)fumarate] and poly(ethylene glycol)dithiol.

Our laboratory is currently exploring synthetic oligo(poly(ethylene glycol)fumarate) (OPF)-based biomaterials as a means to deliver fibroblasts to promote regeneration of central/partial defects in tendons and ligaments. In order to further modulate the swelling and degradative characteristics of OPF-based hydrogels, OPF crosslinking via a radically initiated, mixed-mode reaction involving poly...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 32  issue 2

pages  31- 39

publication date 2013-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023