Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Authors

  • Ahmad Bitarafan-Rajabi Cardiovascular Interventional Research Center, Department of Nuclear Medicine, Rajaei Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences,Tehran, Iran
  • Arman rahmim Department of Radiology, Johns Hopkins University, Baltimore, Maryland, USA |Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland, USA
  • Hadi Malek Cardiovascular Interventional Research Center, Department of Nuclear Medicine, Rajaei Cardiovascular, Medical, and Research Center, Iran University of Medical Sciences,Tehran, Iran
  • Mohammad Reza Ay Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran|Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
  • Pardis Ghafarian Chronic Respiratory Diseases Research Center, National Research Institute of Tuberculosis and Lung Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran|PET/CT and Cyclotron Center, Masih Daneshvari Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Zahra Etemadi Nuclear Medicine and Molecular Imaging Research Center, Namazi Teaching Hospital, Shiraz University of Medical Sciences, Shiraz, Iran|Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran|Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
Abstract:

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients who underwent myocardial perfusion imaging (MPI). A cardiac phantom with an inserted solid defect was used. The SPECT images were corrected for attenuation using both artifactual CT and CT corrected using metal artifact reduction (MAR). VOI-based analysis was performed in artifactual regions. Results:In phantom studies, mean-of-relative-difference in white-region, between artifact-free attenuation-map without/with MAR were changed from 9.2 and 2.1 to 3.7 and 1.2 for ICD and pacemaker lead, respectively. However, these values for typical patient were 9.7±7.0 and 3.8±2.4 for ICD and pacemaker leads respectively, in white-region. MAR effectively reduces the artifacts in white-regions while this reduction is not significant in black-regions. Conclusion: Following application of MAR, visual and quantification analyses revealed that while quality of CT images were significantly improved, the improvements in the SPECT/CT images were not as pronounced or significant. Therefore cardiac SPECT images corrected for attenuation using CT in the presence of metallic-leads can be interpreted without correction for metal artefacts.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

full text

Learning from implantable cardioverter-defibrillator leads in children.

I f you want something broken, give it to your kid. That truism applies to many items, from toys to technology. The article describing the results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) study by Atallah et al 1 in this issue of Circulation provides sobering but important evidence that this also applies to implantable cardioverter-defibrillator (ICD) leads. Most IC...

full text

Is the transvenous extraction of cardioverter-defibrillator leads more hazardous than that of pacemaker leads?

BACKGROUND Leads used for low-voltage and high-voltage therapy delivered by implantable cardioverter-defibrillators (ICD) differ from low-voltage pacemaker (PM) leads in their diameter and complexity of structure. Although there are reports showing that the extraction of ICD leads may be hazardous, due to firm adhesions to the vascular and chamber walls of high-voltage therapy coils, clinical e...

full text

Magnetic resonance imaging safety in pacemaker and implantable cardioverter defibrillator patients: how far have we come?

Magnetic resonance imaging (MRI) has long been regarded a general contraindication in patients with cardiovascular implanted electronic devices such as cardiac pacemakers or cardioverter defibrillators (ICDs) due to the risk of severe complications and even deaths caused by interactions of the magnetic resonance (MR) surrounding and the electric devices. Over the last decade, a better understan...

full text

Is the implantable cardioverter-defibrillator cost-effective?

Three-and four-dimensional cardiovascular ultrasound imaging: a new era for echocardiography. In vitro evaluation of an ultrasonic three-dimensional imaging and volume system. A new integrated system for three-dimensional echocardiographic reconstruction: development and validation for ventricular volume with application in human subjects. [5] Gopal AS, Keller AM, Shen Z et al. Three-dimensiona...

full text

Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads.

OBJECTIVES We report a series of patients with severe tricuspid valve regurgitation due to a permanent pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) lead. BACKGROUND Severe tricuspid regurgitation caused by a PPM or ICD lead is an under-recognized but treatable etiology of severe right heart failure. METHODS We reviewed the records of 41 patients who underwent tricuspid va...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 26  issue 1

pages  35- 46

publication date 2018-01-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023