Investigation of lung normal tissue doses in lung tumors radiation therapy using both gated and conventional radiotherapy
Authors
Abstract:
Introduction: In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the clinical target volume (CTV). With the margin increasing, a larger volume of normal tissue will be exposed to high-dose. In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), using the NCAT digital phantom. Materials and Methods: Different series of CT images of sample patients were created, using the NCAT digital phantom and MATLAB software. Lesions with diameters of 3, 4 and 5cm were located in different positions of lung (left upper and lower lobes, right upper and lower lobes) in the CT images. Appropriate margins were applied to the CTVs depending on the radiation therapy technique and respiratory cycles. To evaluate the effect of diaphragm extension on the margins to CTV, different diaphragm motions were considered from 2 to 3.5 cm with 0.5 cm intervals. PCRT treatment planning system with Superposition computational algorithm was used to deliver a dose of 60Gy in 30 fractions to the PTVs. Totally, 36 treatment plans were evaluated for each RT technique and Mean lung dos (MLD) and V20 were calculated for both conventional and gated RT techniques. Results: A significant impact on MLD and V20 reduction was seen in lung normal tissue in gated RT up to 5Gy and 37%, respectively. Conclusion: In all cases, gated RT has a superior advantage compared to conventional RT, especially for the lesions that are near to the diaphragm.
similar resources
Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.
Introduction: The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer. Materials and Methods: Two CT scan was performred for each pati...
full textبررسی دز رسیده به بافت سالم ریه در پرتودرمانی تومورهای ریوی به دو روش پرتودرمانی گیتد و معمولی
In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the CTV. With the margin increasing, a larger volume of normal tissue will be exposed to high-dose. In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), using the NCAT digital phantom. Different series of CT im...
full textThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
full textContent and characterization of plasminogen activators in human lung tumors and normal lung tissue.
The plasminogen activator content of surgically removed lung cancers, as well as that of adjacent normal lung tissue has been determined quantitatively. Optimum conditions for the quantitative extraction have been worked out using a modification of the technique described by Nagy et al. (Int. J. Cancer, 19:614-620, 1977) which utilizes a buffered solution of the non-ionic detergent Triton X-100...
full textStereotactic Body Radiation Therapy (SBRT) for lung cancer patients previously treated with conventional radiotherapy: a review
Lung cancer continues to be one of the most prevalent malignancies worldwide and is the leading cause of death in both men and women. Presently, local control rates are quite poor. Improvements in imaging and radiation treatment delivery systems however have provided radiation oncologists with new tools to better target these tumors. Stereotactic body radiation therapy (SBRT) is one such techni...
full textEvaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study
Background: The dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. Therefore, it becomes necessary to quantify these deviations.Objective: The present study has been undertaken to find out inter- and intra- lung density variations and its dosi...
full textMy Resources
Journal title
volume 15 issue Special Issue-12th. Iranian Congress of Medical Physics
pages 174- 174
publication date 2018-12-01