Investigating Efficiency of Shotcrete for Retrofitting Masonry Buildings

Authors

  • Abdolkarim Abbasi Assistance Professor, Department of Civil Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
  • Mohsen Yazdanian Young Researchers and Elite Club, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
Abstract:

One of a feasible and efficient method to retrofit structures is spraying shotcrete which is widely applied around the world. Shotcrete is concrete with fine aggregates which are sprayed through a hose and by air pressure coat at high velocity onto a surface. In the current research, three masonry schools from different regions of Iran are selected. The retrofitted wall surfaces have been prepared and became flatted, and Schmidt hammer and Ultrasonic tests are performed for each point. The results from the experimental investigation are compared with each other, and some experimental results are compared with theoretical results. To investigate the seismic behavior of structures, one of the schools is chosen and then finite element method is used to do time history analysis regarding four ground motions record. Finally, there was an agreement between experimental and theoretically dynamic modules. In retrofitted conditions, the obtained frequencies are more than the un-retrofitted condition and dynamic time- history analyses have shown that in retrofitted condition, the displacements will decrease and the seismic performance of structure will increase considerably.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Efficiency of strengthening techniques assessed for existing masonry buildings

The Azores archipelago is a zone with a vast cultural heritage, presenting a building stock mainly constructed in traditional stone masonry. It is known that this type of construction exhibits poor behaviour under seismic excitations; however it is extensively used in seismic prone areas, such as this case. The 9th of July of 1998 earthquake was the last seismic event in the islands, leaving ma...

full text

Retrofitting Masonry Walls with Carbon Mesh

Static-cyclic shear load tests and tensile tests on retrofitted masonry walls were conducted at UAS Fribourg for an evaluation of the newly developed retrofitting system, the S&P ARMO-System. This retrofitting system consists of a composite of carbon mesh embedded in a specially adapted high quality spray mortar. It can be applied with established construction techniques using traditional const...

full text

Seismic retrofitting of non-engineered masonry in rural Nepal

One of the greatest causes of casualties in major earthquakes around the world is the collapse of non-engineered masonry buildings (those built without engineering input). Yet by definition non-engineered structures remain largely outside of the scope of modern engineering research, meaning that the majority of those at risk often remain so. A further barrier to realising research in this field...

full text

Retrofitting Listed Buildings: Measures, Savings and Requirements

The paper presents a case study where the energy demand for a listed building constructed in 1900 is reduced. Many older buildings are listed and have restrictions that include the entire building or that include only its exterior. For the building presented, only its exterior facade is listed. The paper demonstrates measures for the improvement of the thermal insulation of the building with so...

full text

Uncertainty in Seismic Capacity of Masonry Buildings

Seismic assessment of masonry structures is plagued by both inherent randomness and model uncertainty. The former is referred to as aleatory uncertainty, the latter as epistemic uncertainty because it depends on the knowledge level. Pioneering studies on reinforced concrete buildings have revealed a significant influence of modeling parameters on seismic vulnerability. However, confidence in me...

full text

A Retrofitting Framework for Pre-Northridge Steel Moment-Frame Buildings

A case study of retrofitting a 20-story pre-Northridge steel moment-frame building is presented. Twelve retrofit 4 schemes are developed with varying degrees of intervention. Three retrofitting techniques are considered: up5 grading the brittle beam-to-column moment resisting connections, and implementing either conventional or 6 buckling-restrained brace elements within the existing moment-fra...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 5  issue 1

pages  47- 66

publication date 2017-02-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023