Improvement of Transient Voltage Profile Using Power Control of the DFIG-Based Wind Farm Under Severe Voltage Dip Event
Authors
Abstract:
Improving transient voltage stability is one of the most important issues that must be provided by doubly fed induction generator (DFIG)-based wind farms (WFs) according to the grid code requirement. This paper proposes adjusted DC-link chopper based passive voltage compensator and modified transient voltage controller (MTVC) based active voltage compensator for improving transient voltage stability. MTVC is a controller-based approach, in which by following a voltage dip (VD) condition, the voltage stability for the WF can be improved. In this approach, a voltage dip index (VDI) is proposed to activate/deactivate the control strategy, in which, two threshold values are used. In the active mode, the active and reactive power are changed to decrease the rotor current and boost the PCC voltage, respectively. Based on the control strategy, in a faulty grid, DFIG not only will be able to smooth DC-link voltage fluctuations and reduces rotor overcurrents but also it will increase the voltage of point of common coupling (PCC). Therefore, it improves transient voltage stability. The simulation results show the effectiveness of the proposed strategy for improving voltage stability in the DFIG.
similar resources
Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
full textLow voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips
This paper proposes a competent and effective scheme to enhance the ride-through capability of DFIGbased wind turbines under unbalanced voltage dip conditions. The proposed method is realized through joint use of the rotor-side converter control and a three-phase stator damping resistor (SDR) placed in series with the stator windings. By means of an asymmetrical SDR idea, during the unbalanced ...
full textdegradation of oil impregnated paper insulation under influence of repetitive fast high voltage impulses
در طی سالهای اخیراستفاده ازمنابع انرژی تجدید پذیر در شبکه های مدرن بنا به دلایل زیست محیطی و اقتصادی به طور گسترده استفاده شده است همچون نیروگاههای بادی و خورشیدی .ولتاژتولیدی این نیروگاهها اغلب به فرم dc می باشد وادوات الکترونیک قدرت به عنوان مبدل و پل بین شکل موج dc وac استفاده می شوند.این پروسه باعث ایجاد پالسهایی برروی شکل موج خروجی می شود که می تواند وارد تجهیزات قدرت همچون ترانسفورماتور ی...
15 صفحه اولWind farm based on DFIG entirely interfaced with 14-node distribution network: power control and voltage regulation
Abstract: High penetration of wind energy into the network may introduce stability and power quality problems due to the fluctuating nature of the wind and the increasing complexity of the power system. This paper describes a novel approach to voltage and power control of a radial electrical distribution network, using a wind farm. The wind farm consists of seven 75 kW induction generators (DFI...
full textLow Voltage Ride through Capability Improvement of Dfig Based Wind Turbine Using Statcom
This paper studies a control strategy to improve low voltage ride through (LVRT) capability of doubly fed induction generator (DFIG)-based wind turbine (WT). This solution is based on the DFIG with Crowbar circuit control and the installation of STATCOM which is connected at the point of common coupling (PCC). The simulation model of WTs with STATCOM is built using the environment MATLAB/Simuli...
full textapplication of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولMy Resources
Journal title
volume 16 issue 3
pages 313- 324
publication date 2020-09
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com