Hybrid Series & Shunt Active DC Line Conditioner

Authors

  • A. Yazdian
  • M. Mohamadian
  • S. M. Dehghan
Abstract:

In this paper a hybrid active DC line conditioner for fluctuations and ripples reduction in voltage and current of DC power systems is proposed. Malfunctions in operation of equipments and systems which are supplied by low quality distribution power systems are one of the main effects of DC voltage ripple. In the proposed configuration a hybrid system including series and shunt active line conditioners for ripple reduction of load voltage and source current is used. Simulation and experimental results are provided to show the performance of the proposed configuration in different states.

similar resources

Performance Investigation of Active Power Line Conditioner using Simulink

Active power conditioners have been developed over the years to solve the problems to improve power quality. Among which shunt active power conditioners is used to eliminate load current harmonics and reactive power compensation. The controller ensures that the dc-side capacitor voltage is nearly constant with small ripple besides extracting fundamental reference currents. The PLL block assists...

full text

Modelling of Three-phase Shunt Hybrid Active Power Filter

The three-phase Shunt hybrid APF topology for harmonic mitigation in low and medium voltage power distribution systems consists of a VSI based three phase shunt active filter (SAF) and tuned passive filters (TPF) connected in parallel with the load. This chapter discusses the modelling of shunt active filter and design of filter interfacing inductor, DC bus capacitor, tuned passive filters. It ...

full text

Harmonic Mitigation Using Inverter Based Hybrid Shunt Active Power Filter

With the rapid developments and use of non linear loads, the controlling over the harmonic current to get and maintain power quality is becoming more important. Active power filters has been used to compensate the harmonic pollution in our power system. This paper presents a efficient model to compensate the current harmonics using the inverter based Shunt Active Power Filter, Passive Power Fil...

full text

Voltage Regulation of DC-DC Series Resonant Converter Operating in Discontinuous Conduction Mode: The Hybrid Control Approach

Dynamic modeling and control of dc-dc series resonant converter (SRC) especially when operating in discontinuous conduction mode (DCM) is still a challenge in power electronics. Due to semiconductors switching, SRC is naturally represented as a switched linear system, a class of hybrid systems. Nevertheless, the hybrid nature of the SRC is commonly neglected and it is modeled as a purely contin...

full text

Three Phase Active Conditioner for Harmonics Mitigation

The Shunt Active Power Filter is a very essential tool to remove harmonic currents and to reimburse reactive power for nonlinear loads. The fundamental standard of process of a Shunt Active Power Filter is to introduce an appropriate non-sinusoidal current (compensating current) into the system at the point of common coupling. This research work focuses on the time-domain approach for three-pha...

full text

My Resources

Save resource for easier access later