Generating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method

Authors

  • Fatemeh Maghsoodinia Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Roghayeh Kamran Samani Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
Abstract:

Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department workload and costs, in this study, brain synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images were generated using Atlas-based method; consequently, just one type of image (CT or MR) is taken from the patient. Material and Methods: The dataset included MR and CT paired images from 10 brain radiotherapy (RT) patients. To generate sCT/sMR images, first each MR/CT Atlas was registered to the MR/CT target image, the resulting transformation was applied to the corresponding CT/MR Atlas, which created the set of deformed images. Then, the deformed images were fused to generate a single sCT/sMR image, and finally, the sCT/sMR images were compared to the real CT/MR images using the mean absolute error (MAE). Results: The results showed that the MAE of sMR (sT1w/sT2w) was less than that of sCT images. Moreover, sCT images based on T1w were in better agreement with real CT than sCT-based T2w. In addition, sT1w images represented a lower MAE relative to sT2w. Conclusion: The CT target image was more successful in transferring the geometry of the brain tissues to the synthetic image than MR target.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Generating the synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images of the brain using atlas based method

Introduction: Radiation therapy planning (RTP) is one of the clinical applications in which both CT scan and MRI are used. MR and CT images are applied to determine the target volume and calculation of dose distribution, respectively. In addition, using two imaging modalities increases the department workload and cost. In this study, an algorithm was presented to create synthet...

full text

MR-OPERA: A Multicenter/Multivendor Validation of Magnetic Resonance Imaging-Only Prostate Treatment Planning Using Synthetic Computed Tomography Images.

PURPOSE To validate the dosimetric accuracy and clinical robustness of a commercially available software for magnetic resonance (MR) to synthetic computed tomography (sCT) conversion, in an MR imaging-only workflow for 170 prostate cancer patients. METHODS AND MATERIALS The 4 participating centers had MriPlanner (Spectronic Medical), an atlas-based sCT generation software, installed as a clou...

full text

Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review

Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...

full text

Computed Tomography and Magnetic Resonance Images of Adrenocortical Oncocytoma Cases

We present two cases of adrenocortical oncocytomas that were well-delineated on multi-detector computed tomography and magnetic resonance imaging. The images showed a well-enhanced large mass with multiple stippled calcifications in a 10-yr-old girl who was consulted due to precocious puberty. A well-enhanced solid mass with necrotic components was incidentally noticed in a 54-yr-old man. These...

full text

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 16  issue 3

pages  189- 194

publication date 2019-05-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023