Flexural Behavior of Lightweight Concrete Beams Reinforced with GFRP Bars and Effects of the Added Micro and Macro Fiber

Authors

  • M. R. Esfahani Department of civil engineering, Ferdowsi university of Mashhad, Mashhad, Iran
  • Peyman Homami Department of Civil Engineering, Kharazmi University, Tehran, Iran
Abstract:

This study evaluated the effect of macro steel fiber (SF), micro glass fiber (GF) and micro polypropylene fiber (PF) in lightweight aggregate concrete, (LWAC) beams reinforced with glass fiber reinforced polymer (GFRP) bars. Firstly, concrete mixtures with different volume fractions of GF, PF and SF were tested up to compressive strength, then determine the optimum fiber content GF, PF and SF added into LWAC mix by 0.3%, 0.8% and 0.25% by the volume of concrete, respectively. Meanwhile, eight rectangular cross-section beams with 100 mm (width) × 200 mm (depth) × 1500 mm (length) were tested by four-point bending beam test up to the ultimate load. The GFRP bars were used to reinforce all beams. The failure modes, load-deflection behavior, ductility, flexural capacity and energy absorption were compared in the test results. The experimental results shown added fibers into LWAC improved the flexural capacity, ductility and energy absorption also enhanced moment capacity by 10.07% to 110%. The results indicated that failure modes of GF and PF specimens were in good consistency with the ACI 440.1R-06 predicted failure modes, but for SF specimens, only concrete crushing failure modes accrued. At the end step, the correction factor ( ) obtained from calculated of the experimental results with the flexural capacity according to the ACI 440.1R-06 and ISIS design manual No. 3.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Numerical Study on the Flexural Behaviour of Concrete Beams Reinforced by GFRP Bars

Enhancement of the response of reinforced concrete (RC) beams using fiber-reinforced polymer (FRP) reinforcement bars has become a popular structural technique over the past two decades due to the well-known advantages of FRP composites including their high strength-to-weight ratio and excellent corrosion resistance. Thisstudy presents n...

full text

Flexural Cracks in Fiber-Reinforced Concrete Beams with Fiber-Reinforced Polymer Reinforcing Bars

Fiber-reinforced polymer (FRP) reinforcing bars have aTtracted considerable 0llellli0l1 for applications where corrosion of steel reinforcement is problemaric. Due 10 rhe generally low elastic modulus and poor bond clwracreristics of FRP as coil/pared 10 steel reinforcing bars, the use of FRP results in IGI:i?er crack widlhs under senJice loads. Fiber-reinforced concrete (FRe) is proposed for u...

full text

Glass Fiber Reinforced Polymer (GFRP) Bars for Enhancing the Flexural Performance of RC Beams Using Side-NSM Technique

Reinforced concrete (RC) structures require strengthening for numerous factors, such as increased load, modification of the structural systems, structural upgrade or errors in the design and construction stages. The side near-surface mounted (SNSM) strengthening technique with glass fiber-reinforced polymer (GFRP) bars is a relatively new emerging technique for enhancing the flexural capacities...

full text

Flexural Behavior of Reinforced HPFRCC Beams

High Performance Fiber Reinforced Cementitious Composite (HPFRCC) materials exhibit strain hardening behavior with multiple cracking under tensile loading. In this paper, experimental and parametric studies are performed to assess the influence of using HPFRCC material instead of normal concrete in reinforced concrete beams. After calibrating the experimental results, the analytical results inc...

full text

Long-Term Flexural Behaviors of GFRP Reinforced Concrete Beams Exposed to Accelerated Aging Exposure Conditions

This study investigates the impact of accelerated aging conditions on the long-term flexural behavior and ductility of reinforced concrete (RC) members with glass fiber-reinforced polymer (GFRP) bars (RC-GFRP specimen) and steel bars (RC-steel specimen). A total of thirty six specimens were designed with different amounts of reinforcement with three types of reinforcing bars (i.e., helically wr...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 52  issue 2

pages  349- 363

publication date 2019-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023