Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

Authors

  • Mohamad Yousefi Sooteh Medical Physics Department, Tabriz University of Medical Sciences, Tabriz, East Azerbaijan, Iran
  • Nader Riahi Alam Physics and Medical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran/ Tel: +98-21- 66466383, Fax: +98-21- 88973653, E-mail: [email protected]
  • Sadegh Shurche Physics and Medical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran
Abstract:

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in three dimensions. Materials and Methods: In this study, we designed a new phantom containing 13,824 reference features (control points) with AutoCAD software, fabricated it with a 3D printer, and filled it with vegetable oil. This phantom was tested on the Siemens 3 Tesla Prisma MRI model using a 64-channel head coil. We used imaging from a six-slice CT scan (Siemens) as a reference and matched the reference features in the MRI images with the CT-scan images. To achieve this, we used a three-dimensional reference feature model. Reproducibility on the phantom was investigated with three different imaging sessions per day for three different days. Results: The geometric distortion in the 3D results was found to be due to field non-uniformity and nonlinearity of the gradients and its reproducibility. The mean Euclidean distance error for MRI volume was less than 1 mm. The maximum Euclidean error was 1.5 mm. Distortion in the whole volume is pronounced exclusively at the edges of the magnetic field. Conclusion: As with other investigations carried out in our work, the amount of distortion in the middle of the field was less than at its sides. This phantom can be used to check the distortion filters on the device. Also, this phantom can be used to study geometric distortion in scenarios that require a small study volume, such as prostate studies.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

full text

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

full text

Geometric Distortion in Structural Magnetic Resonance Imaging

Geometric distortion, an undesirable image artifact, is an inferior aspect associated with magnetic resonance imaging (MRI). Although slight distortions in MR images often have no consequences in reaching clinical conclusions, geometric distortions can make significant differences in certain MR applications such as, for example, stereotactic localization in radio-surgery and MR image-guided bio...

full text

Design and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging

Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...

full text

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  133- 133

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023