Experimental Study for Strength Capacity of Cold-Formed Steel Joists Connections with Consideration of Various Bolts Arrangements

Authors

  • Ehsan Mobedi Ph.D. Candidate, Department of Civil Engineering, University of Science and Culture, Tehran, Iran
  • Hooman Ghasemi Assistant Professor, Qazvin Branch, Islamic Azad University, Qazvin, Iran, and Formerly PhD of Structural Engineering. Auburn University, USA
  • Hossein Parastesh Associate Professor, Department of Civil Engineering, University of Science and Culture, Tehran, Iran
  • K Amjadiyan Graduate Student, Department of Civil Engineering, University of Science and Culture, Tehran, Iran
Abstract:

With growth the construction technologies, Cold-Formed Steel, CFS, sections are widely used in ordinary steel buildings because of some advantages such as light weight, ease of installation, decrease in cost, and increase in speed of operation. Using the bolted connections for CFS joist is one of the best details for steel structures. The main objective of this study is to conduct an experimental research to evaluate the load carrying capacity of bolted connections based on various bolts arrangement. Ten full scale joist-beam connections are tested under the incremental gravity load. The variable parameters are the arrangement of bolts, and thickness of CFS sheets. The joist sections made of two C-shaped, which are back-to-back connected using self-drilling screw bolts in the web. The arrangement of bolts connection and steel sheet thickness are considered as two major factors to improve the load carrying capacity. Base on the obtained results, it was observed that increasing the number of the bolts and their spacing from the neutral axes led to the additional load carrying capacity. Furthermore, it can be concluded that the thickness of CFS sheets play an effective role for load carrying capacity of connections.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Review on Cold-Formed Steel Connections

The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the...

full text

Cyclic Behavior of Cold-Formed Steel Stud-to-Sheathing Connections

This series of experiments aims to characterize the cyclic behavior of cold-formed steel (CFS) stud-to-sheathing connections. This connection provides the key energy dissipating behavior in wood sheathed CFS shear walls, and provides bracing to the studs under gravity and out-of-plane loads. A simple testing rig is developed consisting of two CFS lipped channels facing toe-to-toe connected on t...

full text

Structural behavior of cold-formed stainless steel bolted connections

This paper presents a series of tests on cold-formed stainless steel bolted connections. The test specimens were fabricated from three different types of stainless steel, including austenitic stainless steel EN1.4301 (AISI 304) and EN1.4571 (AISI 316Ti having small amount of titanium) as well as lean duplex stainless steel EN1.4162 (AISI S32101). The material properties of the three types of st...

full text

non-linear study of various slit shear walls in steel structures

seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...

15 صفحه اول

Simulation of conventional cold-formed steel sections formed from Advanced High Strength Steel (AHSS)

The objective of this paper is to explore the potential impact of the use of advanced high strength steel (AHSS) to form traditional cold-formed steel structural members. In this study, shell finite element models are constructed, and geometric and material nonlinear collapse analysis performed, on simulated lipped channel cross-section cold-formed steel members roll-formed from AHSS. AHSS shee...

full text

Design of Cold-Formed Steel Screw Connections with Gypsum Sheathing at Ambient and Elevated Temperatures

Abstract: Load-bearing cold-formed steel (CFS) walls sheathed with double layers of gypsum plasterboard on both sides have demonstrated good fire resistance and attracted increasing interest for use in mid-rise CFS structures. As the main connection method, screw connections between CFS and gypsum sheathing play an important role in both the structural design and fire resistance of this wall sy...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 7  issue 2

pages  61- 70

publication date 2019-05-01

By following a journal you will be notified via email when a new issue of this journal is published.