Experimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations
Authors
Abstract:
Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in pure component liquids with same physical properties. Several reasons should be responsible for this phenomenon, but mainly it could be related to preferential evaporation of the more volatile component(s) during bubble formation. In this article, the performances of major existing correlations to the present experimental data including pure and binary mixture liquids are discussed. It is shown that it is impossible to predict the accurate value of boiling heat transfer for liquid mixtures and even pure liquids by any existing correlations over all ranges of concentrations or heat fluxes. In this investigation, the Schlünder correlation - as a model with excellent theoretical basis - has been modified; however some models provide superior performance in our experimental range. Originally, it is stated by different authors that B0 - the ratio of the interfacial area of heat transfer to those of mass transfer as a tuning parameters in Schlünder model - is too complicated to predict and should be fitted empirically as a function of heat flux, density and pressure for any given binary system. In this investigation, B0, the mentioned tuning parameter has been basically derived based on the analogy of the mass, heat and momentum transfer. As the results, the average error of Schlünder model in a wide range of boiling parameters has been significantly reduced.
similar resources
experimental investigation in pool boiling heat transfer of pure/binary mixtures and heat transfer correlations
nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. in this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in pure ...
full textPool Boiling Heat Transfer in Water/Amines Solutions
In this investigation, nucleate boiling heat transfer coefficients were experimentally measured during pool boiling of mixtures, consisting of water/monoethanolamine and water/diethanolamine on a horizontal heating rod, under atmospheric pressure. The experiment was carried out below 205 kW.m-2 heat flux, over a wide range of concentrations. These experiments include, measurement of pool boilin...
full textHeat transfer in nucleate pool boiling of multicomponent mixtures
Steady state pool boiling heat transfer coefficients have been obtained experimentally for acetone–isopropanol–water and acetone–MEK (methyl ethyl ketone)–water ternary systems. The data show that, for a given heat flux, the heat transfer coefficients of mixtures are lower than those obtained for pure components constituting the mixture. The measured heat transfer coefficients were compared wit...
full textExperimental Study for Investigating the Mechanism of Heat Transfer near the Critical Heat Flux in Nucleate Pool Boiling
Heat transfer coefficient in nucleate pool boiling near critical heat flux at least one orderhigher than the convectional heat transfer modes. In this paper, an experimental setup isdesigned and fabricated to investigate the mechanism of heat transfer from boiling surface tobulk liquid near critical heat flux. The images of pool boiling near the high heat flux regionreveals that the individual ...
full textExperimental Investigation of Boiling and Condensation Heat Transfer of a two Phase Closed Thermosyphon
In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of the thermosyphon. The experimental boiling and condensation heat transfer coefficients inside the thermosyphon were com...
full textExperimental Investigation of Boiling and Condensation Heat Transfer of a Two Phase Closed Thermosyphon
In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of a thermosyphon with a copper tube having 25 and 32 mm inside and outside diameters. Distilled water was used as the wor...
full textMy Resources
Journal title
volume 27 issue 3
pages 135- 150
publication date 2008-09-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023