Evaluation of Root Canal Transportation using Bio Race and K -Flexo file instruments: using cone-Bean Computed

Authors

  • Mollaei, Melika
  • ,
  • haghanifar, sina
Abstract:

Background & Aim: Deviation from the original shape of the canal leads to poor filling and lack of proper canal seal and consequently to the failure of root treatment The aim of this experimental study was to determine the extent of apical transportation after instrumentation with hand K-Flexofile and BioRace rotary instruments by cone-beam computed tomography (CBCT). Material and Methods: In this experimental ex-vivo study Fifty-four extracted maxillary first molars with 19-22 mm length and 5-25 degrees of curvature were selected. The mesiobuccal canals were prepared using either the K Flexo file and Bio Race rotary files. To compare apical transportation, CBCT images were taken before and after canal preparation. The apical transportation values were analyzed using the SPSS software 18  and T-Test, Mann-Whitney ,X2. Results: the mean canal transportation in 1 mm from the apical foramen with Bio Race are more than K Flexo file (P = 0.000).  And the mean canal transportation in 3 mm from the apical foramen with K Flexo file are more than Bio Race (P= 0.047). The Bio Race and K Flexo file  at 2mm from the apical foramen were not significantly different in causing transportation (P= 0.899) Conclusion: Root canal transportation can be seen in all techniques, regardless of the file type used. Although both rotary and manual systems in this study showed some apical transportation, But they both had the same ability to maintain the centrality and curvature of the root canal.  

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Evaluation of Canal Transportation and Centering Ability of Safesider and K-Flexofile: Using Cone-beam Computed Tomography

Abstract Background and aim: Maintaining the original geometry of canal is an important parameter in successful root canal treatment. The aim of this original study was evaluation of apical root canal transportation and centering ability of SafeSider and K-Flexofile using cone beam computed tomography. Materials and Methods: Mesiobuccal root canals of maxillary first molars, with 20-40° curvatu...

full text

cone-beam computed tomographic assessment of canal centering ability and transportation after preparation with twisted file and bio race instrumentation.

use of rotary nickel-titanium (niti) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. cone-beam computed tomography (cbct) has made it possible to accurately evaluate geometrical changes following canal preparation. this study was carried out to compare cana...

full text

Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation

OBJECTIVE Use of rotary Nickel-Titanium (NiTi) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT) has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to co...

full text

cone-beam computed tomography assessment of root canal transportation by neoniti and reciproc single-file systems

introduction: the aim of this in vitro study was to compare the canal transportation of two single-file engine-driven systems, neoniti and reciproc, using cone-beam computed tomography (cbct). methods and materials: forty-five non-calcified roots with mature apices and apical curvature of 15-30 degrees were selected from extracted human maxillary molars for this study. samples were randomly div...

full text

Investigating Root Canal Number and Morphology of Mandibular Anterior Teeth Using Cone Beam Computed Tomography

Background and purpose: Root therapy will be successful if it is done based on a correct diagnosis and appropriate treatment plan with the knowledge of morphology and tooth anatomy, debridement, disinfection, and obturation of the entire root canal system. This study aimed to investigate the number and morphology of canals in root canals mandibular anterior using cone beam computed tomography (...

full text

Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography

INTRODUCTION The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. METHODS One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe a...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 19  issue 4

pages  320- 327

publication date 2022-12

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023