Evaluation of Ferrous-Agarose-Xylenol Gel Properties in Radiation Dosimetry
Authors
Abstract:
Background: Over recent decades, modern protocols of external beam radioÂtherapy and radiation techniques such as intensity-modulated radiotherapy (IMRT) have been developed. These methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3D dosimetry system that has high sensitivity and is capable of measuring and verifying the complex delivery. The ferrous-agarose-xylenol orange (FAX) gels the material properties of which are changed when irradiated have been suggested for such use. Objective: In this study a FAX gel dosimeter was examined for dose linearity for photon and electron beams. Methods: FAX gel was prepared using 0.4 mM (FAS), Fe (NH4)2(SO4)2•6H2O of analytical grade, 25 mM H2SO4 98%, 0.2 mM (XO) xylenol orange-sodium salt, 1% by weight of agarose gel powder and the remaining mass of the solution being highly pure deionized water. FAX gels were exposed to doses up to 20 Gy using 9 MV photon and 6 MeV electron beams by Neptun LINAC. Some general characteristics of FAX such as optical absorbance-dose relationship, sensitivity and reproducibility were analyzed. Results: Although the measurements showed linearity in optical absorbance-dose relationship up to 18 Gy for photons and electrons, oxidation processes continued post-irradiation and storage conditions such as temperature and light affected the response of this dosimeter. The best composition by high sensitivity and stability of dosimeter was found to be 0.4 mM FAS, 0.2 mM XO and 25 mM H2SO4. Conclusion: The above-mentioned FAX gel and UV-visible spectrophotometry as a reader are a sensitive and cheap dosimetry system for radiotherapy.
similar resources
evaluation of ferrous-agarose-xylenol gel properties in radiation dosimetry
background: over recent decades, modern protocols of external beam radio¬therapy and radiation techniques such as intensity-modulated radiotherapy (imrt) have been developed. these methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3d dosimetry system that has high sensitivity and is capable of measuring and verifying the complex ...
full textDiffusion measurement in ferrous infused gel dosimeters
Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe2+ ion to Fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...
full textEvaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.
A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed to a 6 MV photon beam and the depth dose was compared against a diamond detecto...
full textDiffusion properties of bacteriophages through agarose gel membrane.
A simple two-chamber diffusion method was developed to study the diffusion properties of bacteriophages (phages). The apparent diffusion coefficients (D(app)) of Myoviridae phage T4 and filamentous phage fNEL were investigated, and the diffusion of the phages was found to be much slower than the diffusion of three antibiotics, ciprofloxacin, penicillin G, and tetracycline. D(app) of T4 and fNEL...
full textGel dosimetry: The effect of gold nanoparticles on the dose enhancement in the external radiation therapy
Background: Normoxic type MAGICA gel dosimeters are established for dose quantification in three dimensions for radiotherapy. Objective(s): The ability of MAGICA polymer gel was assessed by experimental measurements method for studying the effect of gold nanoparticles (GNPs) in dose enhancement under the external 18MV radiotherapy practices. <...
full textDiffusion measurement in ferrous infused gel dosimeters
Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe ion to Fe ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours after ...
full textMy Resources
Journal title
volume 2 issue 2
pages -
publication date 2012-06-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023