Evaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)
Authors
Abstract:
Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patients' dose. Various factors such as the use of thyroid collar, lead goggles, field size, device type, imaging parameters such as tube voltage and current, alternating or pulsed radiation; type, amount and shape of the filter, 360 degree or partial rotation of tube and scan time, can affect the absorbed dose of the patient in dental CT scans. Among these, the use of thyroid collar (42% reduction), lead goggles (6% reduction),the smallest possible field of view ( up to 90%), pulse irradiation, patient sitting position and 180o rotation angle instead of 360o (more than 50% reduction) cause significant reduction in the organ doses and effective dose of the patients. It should also be kept in mind that measures taken to reduce the patients' dose should not impair image quality and, depending on the patient's condition, the radiographer will select the dose reduction parameters without degrading the image quality.
similar resources
Optimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose
Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...
full textCone beam CT for dental and maxillofacial imaging: dose matters.
The widespread use of cone-beam CT (CBCT) in dentistry has led to increasing concern regarding justification and optimisation of CBCT exposures. When used as a substitute to multidetector CT (MDCT), CBCT can lead to significant dose reduction; however, low-dose protocols of current-generation MDCTs show that there is an overlap between CBCT and MDCT doses. More importantly, although the 3D info...
full text[Comparison of absorbed and effective dose from two dental cone beam computed tomography scanners].
OBJECTIVE This research compared the field of view with the tissue absorbed dose and effective doses using the two dental cone beam computed tomography (CBCT) scanners. MATERIALS AND METHODS Two CBCT devices, an Alphard VEGA and 3DX multi-image micro CT MCT-1, were used. Measurements were made using an Alderson RANDO phantom and thermoluminescence dosimeters (TLDs). The calculation of the eff...
full textEffective dose of cone beam CT (CBCT) of the facial skeleton: a systematic review.
OBJECTIVE To estimate effective dose of cone beam CT (CBCT) of the facial skeleton with focus on measurement methods and scanning protocols. METHODS A systematic review, which adhered to the preferred reporting items for systematic reviews (PRISMA) Statement, of the literature up to April 2014 was conducted. Data sources included MEDLINE®, The Cochrane Library and Web of Science. A model was ...
full textoptimization of parameters in 16-slice ct- scan protocols for reduction of the absorbed dose
introduction in computed tomography (ct) technology, an optimal radiation dose can be achieved via changing radiation parameters such as ma, pitch factor, rotation time and tube voltage (kvp) for diagnostic images. materials and methods in this study, the brain, abdomen, and thorax scaning was performed using toshiba 16-slice scannerand standard aapm and ctdi phantoms. aapm phantom was used for...
full textPatient absorbed dose comparison in CT and Stereoradiography (EOS) imaging during lower limb torsion evaluation using in-vivo and in-vitro dosimetry methods
Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...
full textMy Resources
Journal title
volume 28 issue 4
pages 2521- 2532
publication date 2020-06
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023