Energy Modeling and Simulation including particle technologies within Single and Double Pass Solar Air Heaters

Authors

  • Hossein Ghadamian Department of Energy, Materials and Energy Research Center (MERC), Tehran, Iran
  • Mohammad Aminy Department of Energy, Materials and Energy Research Center (MERC), Tehran, Iran
Abstract:

In order to obtain the best performance of the solar air heaters, it is necessary to find optimum performance conditions. The aim of this research paper is to achieve optimum conditions, by comparing single and double pass solar air heaters. Also, a brief review study of various related research works of all scenarios for a single and double pass and packed bed (including particle technologies) solar air heaters was carried out to observe the challenges of the mentioned systems. Energy modeling and simulation with EES and MATLAB open source code software indicated significant results in efficiency. According to the obtained results, it can be explained that double pass duct not necessarily always increases the overall system energy efficiency. Results of this work indicate, higher ambient air temperature (inlet air temperature) and lower solar irradiation can increase overall energy efficiency of solar double pass systems. More precisely at solar irradiation of 916 W/m2 and inlet air temperature of 302 οK, the system achieves the targeted optimum value in energy efficiency, approximately 90%, which is considerably more than the 65% as an average value.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Double-Pass Flat-Plate Solar Air Heaters with External Recycle

A new device of inserting an absorbing plate to divide a flat-plate channel into two channels with fins attached and external recycling at the ends, resulting in substantially improving the heat transfer efficiency, has been investigated both experimentally and theoretically. The agreement of the theoretical predictions with those measured values from the experimental results is fairly good. Th...

full text

Device Performance Improvement of Double-Pass Wire Mesh Packed Solar Air Heaters under Recycling Operation Conditions

Abstract: The improvement of device performance of a recycling solar air heater featuring a wire mesh packing was investigated experimentally and theoretically. The application of the wire mesh packing and recycle-effect concept to the present study were proposed aiming to strengthen the convective heat-transfer coefficient due to increased turbulence. Comparisons were made among different desi...

full text

Thermal Performance of a Double-pass Solar Air Heater

This study analyzes the thermal performance of solar thermal energy using double-pass absorber plate in Sanandaj, Iran. To this end, a mathematical model was encoded according to the energy and exergy balance equations and solved by MATLAB software. Given the environmental conditions and radiation intensity of a winter day in Sanandaj, the effects of external parameters such as radiation intens...

full text

Comparison between single and double flow plane solar heaters considering gas radiation effect

ABSTRACT: In this paper, the thermal characteristics of single and double flow plane solar heaters with radiating working gas were analyzed and compared by numerical analysis for the first time. The laminar mixed convection gas flow in the heaters was numerically simulated by the CFD method using the finite volume technique. The set of governing equations included the conservation of mass, mome...

full text

Modeling and Design of Solar Energy Systems including Solar Economics

1. F-Chart Method 1.1. Performance and Design of Liquid-Based Solar Heating Systems 1.1.1. Storage Capacity Correction 1.1.2. Collector Flow Rate Correction 1.1.3. Load Heat Exchanger Size Correction 1.2. Performance and Design of Air-Based Solar Heating Systems 1.2.1. Pebble Bed Storage Size Correction 1.2.2. Air Flow Rate Correction 1.3. Performance and Design of Solar Service Water Systems 1...

full text

Efficiency of Recycling Double-Pass V-Corrugated Solar Air Collectors

The influence of recycling on double-pass solar air collectors with welding of the V-corrugated absorber has been studied experimentally and theoretically. Welding the V-corrugated absorber and the recycle-effect concept to the solar air collector was proposed to strengthen the convective heat-transfer coefficient due to turbulence promotion. Both the recycle effect and the V-corrugated absorbe...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 2  issue 2

pages  95- 102

publication date 2016-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023