Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

Authors

  • Mehdi Jahangiri Department of Mechanical Engineering, Faculty of Technical Engineering, Shahrekord Branch, Islamic Azad University, Shahrekord 88137-33395, Iran
  • Mohsen Saghafian Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, 8415683111, Iran
Abstract:

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-sectional area of the artery. Six non-Newtonian models were used to model the non-Newtonian behavior of blood, and their results were compared with the Newtonian model. The results showed that in Power-law and Walburn-Schneck models, unlike other models, shear stress values before and after the stenosis were smaller than Newtonian models. Also, in maximum flow rate, the Carreua, generalized Power-law, Casson, and Carreua-Yasuda models showed a reduction in global importance factor of non-Newtonian behavior, and subsequently, the results approached Newtonian model. In minimum flow rate, the global importance factor of Newtonian behavior increased, which highlighted the importance of Newtonian model. In minimum flow rate, Carreua-Yasuda model was more sensitive to the non-Newtonian behavior of blood compared to Carreua, Casson, and Power-law models. Also, in that time period, Walburn-Schneck was less sensitive to the non-Newtonian behavior of blood. On the other hand, this model did not show sensitivity when the flow rate was at its peak. Power-law model overestimated the global importance factor values. Therefore, Power-law model was not suitable, because it showed extreme sensitivity to dimension. Walburn-Schneck model was not suitable too because it lacked sensitivity.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

EFFECf OF TI-IENON-NEWTONIAN VISCOSITY OF BLOOD ON STEADY AND PULSATILE FLOW IN STENOSED ARTERIES

The effect of non-Newtonian viscosity of blood on the steady and pulsatile flow in a straight rabbit femoral artery with various degrees of stenosis is investigated numerically using a finite element technique for the peak Reynolds numbers of 65 and 100. The Cross model is used to take into account the non-Newtonian viscosity of blood at various shear rates. The infiniteand zeroshear-rate visco...

full text

Physiological Non-newtonian Blood Flow through Single Stenosed Artery

A numerical simulation to investigate the Non-Newtonian modeling effects on physiological flows in a three dimensional idealized artery with a single stenosis of 85% severity is given. The wall vessel is considered to be rigid. Oscillatory physiological and parabolic velocity profile has been imposed for inlet boundary condition. Determination of the physiological waveform is performed using a ...

full text

Numerical Simulation of Nonlinear Pulsatile Newtonian Blood Flow through a Multiple Stenosed Artery

An appropriate nonlinear blood flow model under the influence of periodic body acceleration through a multiple stenosed artery is investigated with the help of finite difference method. The arterial segment is simulated by a cylindrical tube filled with a viscous incompressible Newtonian fluid described by the Navier-Stokes equation. The nonlinear equation is solved numerically with the proper ...

full text

Simulation of a pulsatile non-Newtonian flow past a stenosed 2D artery with atherosclerosis

Atherosclerotic plaque can cause severe stenosis in the artery lumen. Blood flow through a substantially narrowed artery may have different flow characteristics and produce different forces acting on the plaque surface and artery wall. The disturbed flow and force fields in the lumen may have serious implications on vascular endothelial cells, smooth muscle cells, and circulating blood cells. I...

full text

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

full text

Newtonian and Non-Newtonian Blood Flow Simulation after Arterial Stenosis- Steady State and Pulsatile Approaches

Arterial stenosis, for example Atherosclerosis, is one of the most serious forms of arterial disease in the formation of which hemodynamic factors play a significant role. In the present study, a 3-D rigid carotid artery with axisymmetric stenosis with 75% reduction in cross-sectional area is considered. Laminar blood flow is assumed to have both Newtonian and non-Newtonian behavior (generalize...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 7  issue 2

pages  199- 207

publication date 2018-03-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023