Effect of scuba-diving on optic nerve and sheath diameters

Authors

  • Masoud Mehrpour Department of Neurology, Iran University of Medical Sciences, Tehran, Iran.
  • Narges Sadat Shams-Hosseini Department of Occupational and Environmental Medicine, Center Research of Occupational Disease,Firoozgar Clinical Research Developmental Center, Tehran University of Medical Sciences, Tehran, Iran.
  • Saeed Rezaali Islamic Azad University, Tehran Medical Branch, Tehran, Iran.
Abstract:

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one person who had a history of barotraumas was excluded. Each diver then completed a questionnaire on demographic data, medical and diving history. Nineteen other volunteers were selected to represent a control group. A 10-MHz linear ultrasonic probe was used to measure the optic nerve sheath diameters of both eyes in closed and supine position and its relationship with diving history of divers was determined.   Results : It was found that divers have a higher mean optic nerve sheath diameter compared to the normal population as previously reported by other studies. The mean diameter of the left and right optic nerve sheaths were 6.4±0.7, 6.5±0.9 mm respectively and a significant relationship between optic nerve sheath diameter and diving history was found.   Conclusion : Results showed that divers have a higher optic nerve diameter than the general population. However, our result cannot yet be considered as a marker of intracranial pressure in divers as it was conducted on an limited number of subjects and so a bigger study should be undertaken for this purpose.  

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

effect of scuba-diving on optic nerve and sheath diameters

background :there is not any data available about the effect of high bar pressure condition on intracranial pressure. in this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   methods : twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. only one person ...

full text

Optic nerve sheath meningocele

A 53-year-old man presented with a 5-month history of visual loss in his left eye. Visual acuity could be corrected to 20/20 with an increased hyperopic correction. Dilated funduscopy showed faint choroidal folds and elevation of the left optic disc. The coronal view of T2-weighted magnetic resonance imaging demonstrated a fluid-filled dilated sheath surrounding normal optic nerves. General phy...

full text

Primary optic nerve sheath meningioma.

Fifty patients with optic nerve sheath meningiomas have been reviewed with a follow-up of up to 15 years. The median age at onset of their symptoms was 40.0 years. The majority were middle aged females with a slowly progressive lesion. More aggressive lesions were encountered in a younger, predominantly male group of patients with frequent intracranial involvement. Our experience indicates that...

full text

Optic Nerve Sheath in Rats

Fuciis.-Textbook of Ophthalmology (Duane). 1923. Arch. f. Ophrhal., Bd. LXXXVI, S. 155. GILBERT.-Arch. f. Augenheilk., Vol. LXXXVIII, S. 143, 1921. TREACHER COLLINs.-Roy. Lond. Ophthal. Hosp. Reps., Vols. I-XII, p. 273. COLLINS and MAYOU.-Pathology of the Eye, p. 18. PARSONS.-Pathology of the Eye. Vol. I Part I, p. 322, MORAX.-Bull. de la Soc. Fran9. d'Ophtal., Vol. XLIV, p. 365, 1931. HOUWER.-...

full text

Optic nerve sheath diameters in healthy adults measured by computer tomography.

AIM To measure optic nerve sheath diameters (ONSD) in different locations by computer tomography (CT) and to recommend the best location for cases when ONSD is used for intracranial pressure monitoring. METHODS In a prospective cohort study, CT data of 300 healthy adults were analyzed (600 eyes). In all cases, the CT investigation was performed at the Emergency Department because of the vario...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 28  issue 1

pages  577- 581

publication date 2014-01

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023