Effect of Bolus Frequency and Its Thickness in Postmastectomy Three-dimensional Conformal Radiotherapy on Skin Dose for Superposition Algorithm
Authors
Abstract:
Introduction: The postmastectomy radiotherapy uses bolus to improve the coverage close to the skin; however, it needs to be removed in case of severe skin toxicity. This study investigated the effect of bolus parameters (i.e., frequency and thickness) for the superposition algorithm on skin dose in postmastectomy three-dimensional conformal radiotherapy (3D-CRT). Material and Methods: The present study was carried out ona total of 22 patients. First, all the plans were calculated without using bolus. Then, the plans were recalculated using different bolus frequencies (5, 10, 15, 20, 25) and thicknesses (0.5 and 1 cm). To evaluate the dose delivered to the skin, a 2-mm thick skin was profiled, and statistical analysis was performed by studying the dosimetric parameters (i.e., minimum, mean, and maximum) of chest wall skin. Results: The superficial coverage of planning target volume (PTV) was better by using bolus. In the case of skin, the bolus thickness had a significant impact on the minimum and mean doses for all bolus frequencies , while there was no significant effect on the maximum before 20-bolus frequency. The bolus frequency increase demonstrated a significant difference on all dosimetric parameters of the skin , except the maximum showed no significant difference between 0 and 5-bolus frequencies . Conclusion: The obtained results indicated that the bolus use had generally a significant effect on the chest wall skin dosimetric parameters depending on bolus frequency and thickness. Therefore, the choice of bolus frequency and bolus thickness can affect the clinical decisions in certain cases.
similar resources
Evaluation of skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapy
BACKGROUND The study aimed to calculate chest-wall skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapy (3D-CRT) and to provide detailed information in the selection of an appropriate bolus regimen in this clinical setting. METHODS CT-Simulation scans of 22 post-mastectomy patients were used. Chest wall for clinical ...
full textEffect of replacing cochlea contour with inner ear contour on cochlea dose-volume calculations in conventional 2 dimensional and conformal 3 dimensional radiotherapy of brain
Introduction: Sensorineural hearing loss (SNHL) is one of the possible complications of radiotherapy treatment of brain tumors. The auditory system of patients with brain tumors often is placed inside of radiation field and receives a significant amount of radiation dose resulting in hearing loss. The purpose of this study was to compare contouring and delivery dose to cochlea...
full textDosimetric comparison between intensity modulated radiotherapy and three dimensional conformal radiotherapy planning in patients with locally advanced cervical carcinoma
Background: External beam radiotherapy (EBRT) is mainstay of treatment in patients with locally advanced cervical carcinoma (LACC). Three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are mainly used in EBRT. However which one is superior is still controversial. Materials and Methods: Forty patients of LACC treated with IMRT were selected for this study....
full textDosimetric assessment of brass mesh bolus for postmastectomy photon radiotherapy
Brass mesh bolus has been shown to be an acceptable substitute for tissue-equivalent bolus to increase superficial dose for chest wall tangent photon radiotherapy. This work investigated the increase in surface dose, the change in the dose at depth, and the safety implications of higher energy photon beams when using brass mesh bolus for postmastectomy chest wall radiotherapy. A photon tangent ...
full texthistological evaluation of the effect of three medicaments; trichloracetic acid, formocresol and mineral trioxide aggregate on pulpotomized teeth of dogs
چکیده ندارد.
15 صفحه اول3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
full textMy Resources
Journal title
volume 16 issue 6
pages 397- 404
publication date 2019-11-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023