Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Authors

  • Alireza Vajhi Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
  • Hakimeh Sadeghian Tehran Heart Centre, Faculty of Medical Sciences, Tehran University, Tehran, Iran.
  • Majid Masoudifard Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
  • Masoud Rajabioun Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
  • Masoud Selk Ghaffari Department of Clinical Sciences, Faculty of Veterinary Medicine, Islamic Azad University- Karaj Branch, Karaj, Iran.
  • Mohammad Azizzadeh Department of Clinical Sciences, Faculty of Veterinary Medicine, Ferdowsi University of Mashhad, Mashhad, Iran.
Abstract:

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. The following parameters were measured on the both Pulsed-wave Doppler and M-mode echocardiographic images: pre - ejection period (PEP), left ventricular ejection time (LVET), ratio of PEP to LVET (PEP/LVET) and the total electrical-mechanical systole (QAVC). Acceleration time of aortic flow (AT) was also measured by Doppler mode. Results- The following values have been acquired: PEP = 0.067 ± 0.010 s; LVET = 0.188 ± 0.011 s; QAVC = 0.254 ± 0.016 s and PEP/LVET = 0.354 ± 0.054 measured by Mmode echocardiography and PEP = 0.062 ± 0.009 s; LVET = 0.193 ± 0.007 s; QAVC = 0.256 ± 0.011s; PEP/LVET = 0.323 ± 0.051 and AT = 0.080 ± 0.107 s measured by Doppler echocardiography. Conclusion and Clinical Relevance- On Doppler mode, there was a significant correlation between the body weight and PEP and PEP/LVET. M-mode echocardiography showed significant correlation between the body weight and body surface area and QAVC. Results of this study revealed the importance of determination of breed-specific echocardiographic parameters and indices, and evaluating of measured values with range using same method for accurate diagnosis.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Echocardiographic determinations of systolic time intervals in mitral valvular prolapse.

A patient under our care underwent percutaneous transthoracic needle aspiration biopsy of a right upper lobe cavitating lesion of the lung. His clinical state and data on studies of pulmonary function precluded thoracotomy. Flexible fiberoptic bronchoscopic examination had not yielded a diagnosis. The diagnosis before and after the procedure was that of a cavitating epidermoid carcinoma. Immedi...

full text

A Comparison between Brachial and Echocardiographic Systolic Time Intervals

Systolic time interval (STI) is an established noninvasive technique for the assessment of cardiac function. Brachial STIs can be automatically determined by an ankle-brachial index (ABI)-form device. The aims of this study are to evaluate whether the STIs measured from ABI-form device can represent those measured from echocardiography and to compare the diagnostic values of brachial and echoca...

full text

Systolic time intervals in measurement of inotropic response to drugs.

During periods of tachycardia induced by atrial pacing in eight patients, moderate increments in dP/dt(max) and (dP/dt)/CPIP (common produced intraventricular pressure) and moderate reductions in left ventricular ejection time (LVET) and Q-S2 were demonstrated. These changes varied between individuals, but reduction in systolic intervals was consistently less than that reported from populations...

full text

SYSTOLIC TIME INTERVALS IN ATRIAL FIBRILLATION 629 Systolic Time Intervals in Atrial Fibrillation

Forty patients with atrial fibrillation and 20 patients with congestive heart failure and sinus rhythm were studied. Patients were divided into two groups. Group A consisted of 20 patients with atrial fibrillation in whom systolic time intervals were measured. Twenty to 50 beats were analyzed. Five of the patients had high-fidelity measurements of left ventricular pressure simultaneous with det...

full text

Reliability of systolic time intervals in diagnosis of transposition of great arteries in newborn.

SUMMARY The diagnostic echocardiographic features of transposition of the great arteries have been described as (1) abnormal great vessel relations, (2) reversed systolic time intervals. The former has been shown to be unreliable and the systolic time intervals have not been critically evaluated in the neonate. A cardiac opinion was sought in 17 cyanotic neonates, aged 7 to 80 hours in whom ful...

full text

Left Ventricular Systolic Time Intervals

The effects of graded increments of passive head-up tilt on the duration of the systolic time intervals corrected for heart rate were investigated in 15 normal subjects. Head-up tilt caused a prolongation of the pre-ejection period and a shortening of the left ventricular ejection time, while total electromechanical systole diminished minimally. The lengthening of the pre-ejection period and ab...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 03  issue 4

pages  57- 66

publication date 2008-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023