Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback
Authors
Abstract:
Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for 10 patients. For modelling of respiratory motion, the end-exhale phase of these images has been considered as the reference and they were analyzed using neuro-fuzzy method to predict the magnitude of displacement of the lung tumor. Then, the predicted data were used to determine the leaf motion in MLC. Finally, the trained algorithm was figured out using Shaper software to show how MLCs could track the moving tumor and then imported on the Varian Linac equipped with EPID.Results: The root mean square error (RMSE) was used as a statistical criterion in order to investigate the accuracy of neuro-fuzzy performance in lung tumor prediction. The results showed that RMSE did not have a considerable variation. Also, there was a good agreement between the images obtained by EPID and Shaper for a respiratory cycle. Conclusion: The approach used in this study can track the moving tumor with MLC based on the 4D modelling, so it can improve treatment accuracy, dose conformity and sparing of healthy tissues because of low error in margins that can be ignored. Therefore, this method can work more accurately as compared with the gating and invasive approaches using markers.
similar resources
A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates
Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...
full textThe impact of MLC transmitted radiation on EPID dosimetry for dynamic MLC beams.
The purpose of this study was to experimentally quantify the change in response of an amorphous silicon (a-Si) electronic portal imaging device (EPID) to dynamic multileaf collimator (dMLC) beams with varying MLC-transmitted dose components and incorporate the response into a commercial treatment planning system (TPS) EPID prediction model. A combination of uniform intensity dMLC beams and stat...
full textIMRT Treatment Planning on 4D Geometries for the Era of Dynamic MLC Tracking
The problem addressed here was to obtain optimal and deliverable dynamic multileaf collimator (MLC) leaf sequences from four-dimensional (4D) geometries for dynamic MLC tracking delivery. The envisaged scenario was where respiratory phase and position information of the target was available during treatment, from which the optimal treatment plan could be further adapted in real time. A tool for...
full textTracking of Tumor Motion in Lung Cancer Using Patient Specific Finite Element Modeling and 4d-mri Image Data
This paper presents a study that demonstrates the potential of using finite element (FE) lung model constructed using 4D-MRI (3D + time) for tracking tumor motion during a respiratory cycle. A series of volumetric images of one lung cancer patient was acquired over time under free breathing and sorted into respiratory phases. A FE model of the lung with the tumor was constructed using the volum...
full text4D tumor centroid tracking using orthogonal 2D dynamic MRI: implications for radiotherapy planning.
PURPOSE Current pretreatment, 4D imaging techniques are suboptimal in that they sample breathing motion over a very limited "snapshot" in time. Heretofore, long-duration, 4D motion characterization for radiotherapy planning, margin optimization, and validation have been impractical for safety reasons, requiring invasive markers imaged under x-ray fluoroscopy. To characterize 3D tumor motion and...
full textMy Resources
Journal title
volume 9 issue 4
pages 417- 424
publication date 2019-08-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023