Dosimetry evaluation of salivary glands in 3D conformal radiotherapy and intensity modulated radiotherapy in oral tongue cancer
Authors
Abstract:
Introduction: The purpose of this study was to evaluate the dosimetric and radiobiological parameters of salivary glands in treatment of patients with oral tongue cancer by 3D conventional radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) techniques. Materials and Methods: This study was performed on treatment planning of patients with oral tongue cancer in T2-3/N0 cancer staging. In this way, the treatment planning was performed on CT images for 3D-CRT and IMRT techniques (with 5, 7 and 9 fields) for all patients. Then, the homogeneity (HI) and conformity index (CI) of dose in the target volume and maximum, mean does of the salivary glands and normal tissue complication probability of parotid glands were computed and compared between different treatment. Results: Results of this study indicated an increase in HI and CI in IMRT compared to 3D-CRT (up to 61.54% and 28.78%). Moreover, the increase in the number of beams in the IMRT technique can lead to decrease in the mean dose of sublingual glands (up to 9.52%) and decrease in the maximum dose of the submandibular glands (up to 6.93%), while, the use of IMRT with 5 and 7 beams can lead to a significant increase in the probability of xerostomia in parotid gland (up to 8.61%) compare with 3D-CRT technique. Conclusion: It can be concluded that IMRT technique with 9 fields led to improve the salivary glands protection, more homogeneity and conformity in the target volume and reducing the received dose of submandibular and sublingual glands compare to the 3D-CRT in patient with oral tongue cancer.
similar resources
3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
full textIntensity-modulated radiotherapy or volumetric-modulated arc therapy in patients with head and neck cancer: Focus on salivary glands dosimetry.
BACKGROUND Despite radiotherapy (RT) technical improvements, high salivary dysfunction rates are still reported in patients with head and neck squamous cell carcinoma (HNSCC). The purpose of the present study was to report salivary glands dosimetry with volumetric-modulated arc therapy (VMAT) and intensity-modulated RT (IMRT). METHODS Dosimetry of consecutive patients receiving IMRT or VMAT f...
full text3-dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: dosimetric and radiobiologic analysis
background: to analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (imrt) and 3 dimensional conformal radiotherapy (3dcrt) and selection of optimal photon energy for imrt treatments. material and methods: 24 patients with localized prostate carcinoma were planned for 3dcrt and imrt techniques. radiation dose of 54 gy with 2 gy/fraction, was planned to p...
full textDosimetric comparison between intensity modulated radiotherapy and three dimensional conformal radiotherapy planning in patients with locally advanced cervical carcinoma
Background: External beam radiotherapy (EBRT) is mainstay of treatment in patients with locally advanced cervical carcinoma (LACC). Three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are mainly used in EBRT. However which one is superior is still controversial. Materials and Methods: Forty patients of LACC treated with IMRT were selected for this study....
full textIntensity modulated radiotherapy of upper abdominal malignancies: dosimetric comparison with 3D conformal radiotherapy and acute toxicity
BACKGROUND The goal of this study was to assess a possible dosimetric advantage of intensity modulated radiotherapy (IMRT) of upper abdominal malignancies compared to three-dimensional conformal radiotherapy (3DCRT), and to assess the impact of IMRT on acute toxicity. METHODS Thirty-one unselected consecutive patients with upper abdominal malignancies were treated with definitive (n =16) or p...
full textThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
full textMy Resources
Journal title
volume 22 issue 1
pages 99- 106
publication date 2020-01
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023