Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients

Authors

  • Hyo-Kuk Park Department of Radiation Oncology, Yonsei Cancer Center, Seoul
  • Jae-Hwan Cho Department of Radiological Technology, Ansan University, Ansan
  • sungchul Kim Radiological Science, Gachon University Medical Campus, Incheon, Korea
Abstract:

Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree of freedom) treatment couch. The dosimetric effects regarding the application of the rotational setup error were examined by comparing the treatment plans. Results: The mean patient setup errors at the lateral (X-axis), longitudinal (Y-axis), and vertical (Z-axis) directions were 0.1±1.4, 0.0±1.1, and -0.4±1.2 mm, respectively. The pitch, roll, and yaw were -0.29±0.61°,-0.42±0.98°, and -0.53±0.69°, respectively. When an absolute value was taken for the setup error, the mean error was 1.06±0.14 mm at the three translation directions, and the error of rotation was 0.82±0.14°, showing a larger error than that of translation. In terms of the mean dose difference by each region of interest (ROI) before and after correcting for the rotational setup error on the treatment plan, Brain_max was 2.17 Gy, and Brain_mean was 0.28 Gy, whereas the maximum and mean of Brain_stem were -3.58 and -4.43 Gy, respectively. These findings suggested a dose difference according to the correction of the rotational setup error. Conclusion: This study indicated that the dose effect is influenced by the rotational setup error in VMAT of brain tumor patients. Moreover, the 6DoF positional correction could reduce the positional uncertainties and deliver a more accurate dose.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

full text

Dosimetric Evaluation of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Helical Tomotherapy for Hippocampal-Avoidance Whole Brain Radiotherapy

BACKGROUND Whole brain radiotherapy (WBRT) is a vital tool in radiation oncology and beyond, but it can result in adverse health effects such as neurocognitive decline. Hippocampal Avoidance WBRT (HA-WBRT) is a strategy that aims to mitigate the neuro-cognitive side effects of whole brain radiotherapy treatment by sparing the hippocampi while delivering the prescribed dose to the rest of the br...

full text

Dosimetric comparison of intensity‐modulated radiotherapy and volumetric‐modulated arc radiotherapy in patients with prostate cancer: a meta‐analysis

Intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) are two main radiotherapy techniques. The aim of this study is to explore which is the preferred technique in prostate treatment through the related publica-tions and meta-analysis. Two authors independently identified all relevant articles available regarding eligibility criteria on PubMed, Embase, and Cochrane...

full text

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

full text

CBCT-based volumetric and dosimetric variation evaluation of volumetric modulated arc radiotherapy in the treatment of nasopharyngeal cancer patients

OBJECTIVE To investigate the anatomic and dosimetric variations of volumetric modulated arc therapy (VMAT) in the treatment of nasopharyngeal cancer (NPC) patients based on weekly cone beam CT (CBCT). MATERIALS AND METHODS Ten NPC patients treated by VMAT with weekly CBCT for setup corrections were reviewed retrospectively. Deformed volumes of targets and organs at risk (OARs) in the CBCT wer...

full text

Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients

As the advantage of using complex volumetric-modulated arc therapy (VMAT) in the treatment of gynecologic cancer has not yet been fully determined, the purpose of this study was to investigate the dosimetric advantages of VMAT by comparing directly with whole pelvic conformal radiotherapy (CRT) and intensity-modulated radiotherapy (IMRT) in the treatment of 15 postoperative cervical cancer pati...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 16  issue 2

pages  171- 178

publication date 2019-03-01

By following a journal you will be notified via email when a new issue of this journal is published.