Does fluid restriction affect the image quality of skeletal scintigraphy?

Authors

  • Amr Amin Nuclear Medicine Department, Faculty of Medicine, Cairo University, Cairo, Egypt
  • Ayah Nawwar Nuclear Medicine Department, Faculty of Medicine, Cairo University, Cairo, Egypt
  • Mahasen Amin Nuclear Medicine Department, Faculty of Medicine, Cairo University, Cairo, Egypt
Abstract:

Introduction: In Islamic countries in the month of Holy Ramadan many Muslims based on their religious Legislation refuse fluid intake during the fasting time though instructed to drink after injection of Tc-99m Methylene-diphosphonates [Tc-99m MDP] used for skeletal scintigraphy. We aimed to establish whether fluid restriction in Tc-99m MDP skeletal scintigraphy has an impact on its quality. Methods: One hundred forty-four patients referred for skeletal scintigraphy were studied. Group 1 was well hydrated while group 2 was instructed not to drink till imaging. Image quality was assessed using quantitive measures where by the end of imaging, equal regions of interest (ROI) were drawn over the femoral diaphysis, and the contralateral adductor area. The total number of counts from the bone [B] ROI and soft tissue [ST] ROI was expressed as a ratio [B: ST ratio], and a mean value for each group was established. The image quality was also assessed without knowledge of individual’s water intake by a semiquantitative score. Results: No statistically significant difference was found between the B:ST ratio means [P=0.46] and the semiquantitative scores [P=0.42] in both groups. Conclusion: Fluid restriction had no impact on the image quality in Tc-99m MDP skeletal scintigraphy though a higher radiation dose to the urinary bladder wall is anticipated.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

does fluid restriction affect the image quality of skeletal scintigraphy?

introduction: in islamic countries in the month of holy ramadan many muslims based on their religious legislation refuse fluid intake during the fasting time though instructed to drink after injection of tc-99m methylene-diphosphonates [tc-99m mdp] used for skeletal scintigraphy. we aimed to establish whether fluid restriction in tc-99m mdp skeletal scintigraphy has an impact on its quality. me...

full text

Does seasonality affect fluid intake?

Introduction: The proportion of elderly population is increasing globally; however, there are few studies on fluid intake in older adults and specifically on beverage intake throughout the seasons. Objective: To evaluate the effects of changes on fluid intake according to the four seasons in Spanish elderly people. Method: Twenty-eight Spanish subjects aged over 55 years (60.7% females) perform...

full text

Skeletal Scintigraphy.

BACKGROUND Skeletal scintigraphy remains a valuable tool in the initial and subsequent evaluation of the skeletal system in patients with a diagnosis of primary or metastatic neoplasms. METHODS We discuss radiopharmaceuticals, nuclear medicine imaging techniques, and current as well as future oncological applications in the adult population. Pertinent literature was reviewed to describe the a...

full text

How does image noise affect actual and predicted human gaze allocation in assessing image quality?

A central research question in natural vision is how to allocate fixation to extract informative cues for scene perception. With high quality images, psychological and computational studies have made significant progress to understand and predict human gaze allocation in scene exploration. However, it is unclear whether these findings can be generalised to degraded naturalistic visual inputs. I...

full text

does time of day affect quality of breast cancer surgery?

background: time of day can affect the outcome of medical procedures and surgical operations. the current study was designed to assess whether time of day can influence the quality of breast cancer surgery or not. methods: patients who underwent breast cancer surgery and axillary lymph node dissection in tehran, iran between march 2012 and march 2013 were enrolled. surgeries were categorized in...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 21  issue 2

pages  77- 80

publication date 2013-10-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023