Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

Authors

  • A Ghadimi-Moghadam Pediatric Infectious Ward,Yasuj University of Medical Sciences, Yasuj,Iran
  • A Hosseini-Moghadam Student Research Committee,Shiraz University of Medical Sciences, Shiraz,Iran
  • A Soofi Ionizing and Non-ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran
  • F Arian M.Sc Student in Radiobiology and Protection,Paramedical School, Shiraz University of Medical Sciences, Shiraz, Iran
  • L Sanipour M.Sc Student in Radiobiology and Protection,Paramedical School, Shiraz University of Medical Sciences, Shiraz, Iran
  • M Haghani Ionizing and Non-ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran
  • M R Dizavandi MRI Department, Shahid Faghihi Hospital,Shiraz University of Medical Sciences,Shiraz, Iran
  • N Rastegariyan Speech and Language Pathology Department,School of Rehabilitation,Shiraz University of Medical Sciences,Shiraz, Iran
  • S A R Mortazavi Ionizing and Non-ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran
  • S Aghajari M.Sc Student in Radiobiology and Protection,Paramedical School, Shiraz University of Medical Sciences, Shiraz, Iran
  • S M J Mortazavi Ionizing and Non-ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran
  • S Taeb Ionizing and Non-ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran
Abstract:

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and humans to different sources of electromagnetic fields such as cellular phones, mobile base stations, mobile phone jammers, laptop computers, radars, dentistry cavitrons and MRI. This study is to investigate the adverse health effects in MRI workers and also to assess the effect of exposure of MRI workers to static magnetic fields on their cognitive functions. In the first phase of this study a questionnaire was designed to collect information from 120 MRI personnel. The collection of data about the adverse health effects was based on self-reporting by the participants. In the second phase, 47 volunteer university students were asked to continuously move around a 1.5 T MRI scanner. Visual reaction time and working memory tests were performed on all participants before and after the experiment. Forward digit span and backward digit span were used for assessing the working memory. Furthermore, participants were asked to report the symptoms they had experienced during the movement. The first phase of our study showed increased frequencies of adverse health effects in MRI workers. In this study the rates of self-reported symptoms such as a headache, sleep problems, myalgia, palpitation, fatigue, concentration problems, attention problems, nervousness and backpain were possibly affected by static magnetic field. Furthermore we found that reaction time and working memory could be influenced by the movements of the body around a MRI scanner. It can be concluded that movement through a high magnetic field can also lead to some adverse cognitive effects in MRI staff.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

does exposure to static magnetic fields generated by magnetic resonance imaging scanners raise safety problems for personnel?

mri workers are occupationally exposed to static and time-varying gradient magnetic fields.  while the 24-hour time-averaged exposure to static magnetic fields is about a few mt, the maximum static field strength can be as high as 500 mt during patient set up. over the past several years, our lab has performed extensive experiments on the health effects of exposure of animal models and humans t...

full text

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

full text

Open magnetic resonance imaging (MRI) scanners.

(1) In most MRI scanners, the patient examination table fits inside a long cylindrical tube. Large patients cannot be accommodated, and some persons experience claustrophobic reactions. Open MRI systems, in which the patient is placed between two plates, overcome these disadvantages. (2) Open MRI scanners are widely used in health care. High-field closed MRI systems are preferred for many exami...

full text

Software Tools for the Analysis of Functional Magnetic Resonance Imaging

Functional magnetic resonance imaging (fMRI) has become the most popular method for imaging of brain functions. Currently, there is a large variety of software packages for the analysis of fMRI data, each providing many features for users. Since there is no single package that can provide all the necessary analyses for the fMRI data, it is helpful to know the features of each software package. ...

full text

Safety of strong, static magnetic fields.

Issues associated with the exposure of patients to strong, static magnetic fields during magnetic resonance imaging (MRI) are reviewed and discussed. The history of human exposure to magnetic fields is reviewed, and the contradictory nature of the literature regarding effects on human health is described. In the absence of ferromagnetic foreign bodies, there is no replicated scientific study sh...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 8  issue 3

pages  -

publication date 2018-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023