Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

Authors

  • Arash Mahboubi Food Safety Research Center, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.|Department of Pharmaceutics, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Mahdieh Farhangi Department of Pharmaceutics, Faculty of Pharmacy, Hormozgan University of Medical Sciences, Bandar Abbas, Iran.
  • Marjan Alviri Department of Pharmaceutics, Faculty of Pharmacy and Pharmaceutical Sciences, Tehran Medical Sciences, Islamic Azad University, Tehran 193956466, Iran.
  • Minoo Afshar Department of Pharmaceutics, Pharmaceutical Sciences Branch, Islamic Azad University (IAUPS), Tehran, Iran.
Abstract:

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:10). The flow rate was set at 1.5 ml/min and Dexpanthenol concentration was determined at λmax = 205 nm. The HPLC analysis method was validated in the terms of linearity, precision, accuracy, specificity, sensitivity according to International Conference on Harmonization (ICH) guidelines. The results showed that the retention time was 8 min and no interferences were observed from the formulation excipients and stress degradation products. Linear regression analysis of data for the calibration plot showed a linear relationship between peak area and concentration over the range of 10 - 100 μg/ml; the regression coefficient was 0.996 and the linear regression equation was y = 20.011 x + 146.83. This HPLC method was precise and accurate in the range of 10 – 100 μg/ml. Also the dexpanthenol concentration in artificial tear formulation was determined by this HPLC method, which was in accordance with the label claimed. This validated HPLC method could be used for routine analysis, quality control and the stability of analysis of eye gel containing dexpanthenol formulations.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Development and validation of a stability indicating RP-HPLC method for the determination of Rufinamide

A stability-indicating RP-HPLC method was developed and validated for the determination of Rufinamide in tablet dosage forms using C 18 column (250 mm×4.6 mm, 5 μm) with mobile phase consisting of water-acetonitrile (40:60, v/v) with a flow rate of 0.8 mL/min (UV detection 215 nm). Linearity was observed over the concentration range 1.0-200 μg/mL (R2=0.9997) with regression equation y=113190 x+...

full text

Development and Validation of Stability Indicating Rp-hplc Method for Determination of Β-acetyldigoxin

Objective: The objective of the present study was to develop and validate a novel stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for determination of β-acetyldigoxin, an active pharmaceutical ingredient (API). Methods: The chromatographic separation was carried out on Agilent Technologies 1200 series HPLC system equipped with photo diode array detecto...

full text

Development and validation of stability-indicating RP-HPLC method for the determination of Nabumetone

A simple, precise, and accurate, isocratic, reversed RP-HPLC stability indicating method was developed and validated for determination of Nabumetone (Naphthyl acetic acid derivative). Isocratic RP-HPLC separation was achieved on Inert Sil ODS 3V (5μ, 25 cm× 4.6 mm, i.d.) column using mobile phase consisted of 0.47 g of tetrabutyl ammonium hydroxide sulphate (TBAH) dissolved in 1000 ml of a mixt...

full text

Development and Validation of Stability Indicating HPLC Assay Method for Determination of Tapentadol in Tablet Formulation

The purpose of the research described herein was to develop simple, precise and accurate isocratic stability indicating reversed phase HPLC assay method for determination of Tapentadol solid dosage forms. Isocratic RP-HPLC method was developed on Phenomenex Luna C8 150 4.6mm, 5μm column using mobile phase as methanol – 0.002 M potassium dihydrogen phosphate buffer pH 3.0 (60: 40 v/v) at a flow...

full text

A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form

A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a reten...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 18  issue 2

pages  670- 676

publication date 2019-05-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023