CT-Based Brachytherapy Treatment Planning using Monte Carlo Simulation Aided by an Interface Software

Authors

  • Ahmad Esmaili-Torshabi M.Sc. in Medical Radiation Engineering, Medical Radiation Dept., Faculty of Mechanical Engineering, Shiraz University, Shiraz, Iran
  • Ahmad Mosalaei Professor, Radiotherapy and Oncology Dept., Shiraz University of Medical Sciences, Shiraz, Iran
  • Kamal Hadad Associate Professor, Nuclear Engineering, Center of Radiation Research, Shiraz University, Shiraz, Iran
  • Mohammad Amin Mosleh-Shirazi Assistant Professor, Radiotherapy and Oncology Dept., Center of Research in Medical Physics and Engineering, Shiraz University of Medical Sciences, Shiraz, Iran
  • Reza Faghihi Assistant Professor, Nuclear Engineering, Center of Radiation Research, Shiraz University, Shiraz, Iran
  • Simin Mehdizadeh M.Sc., Nuclear Engineering, Center of Radiation Research, Shiraz University, Shiraz, Iran
  • Vahid Moslemi M.Sc. in Medical Radiation Engineering, Medical Radiation Dept., Faculty of Mechanical Engineering, Shiraz University, Shiraz, Iran
Abstract:

Introduction: In brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. This emphasizes the need for computerized treatment planning. The usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the Manchester system. Nowadays, because of their advantages in locating the source positions and the surrounding tissues, CT and MRI images are replacing conventional radiographs. In this study, we used CT images in Monte Carlo based dose calculation for brachytherapy treatment planning, using an interface software to create the geometry file required in the MCNP code. The aim of using the interface software is to facilitate and speed up the geometry set-up for simulations based on the patient’s anatomy. This paper examines the feasibility of this method in cervix brachytherapy and assesses its accuracy and speed. Material and Methods: For dosimetric measurements regarding the treatment plan, a pelvic phantom was made from polyethylene in which the treatment applicators could be placed. For simulations using CT images, the phantom was scanned at 120 kVp. Using an interface software written in MATLAB, the CT images were converted into MCNP input file and the simulation was then performed. Results: Using the interface software, preparation time for the simulations of the applicator and surrounding structures was approximately 3 minutes; the corresponding time needed in the conventional MCNP geometry entry being approximately 1 hour. The discrepancy in the simulated and measured doses to point A was 1.7% of the prescribed dose.  The corresponding dose differences between the two methods in rectum and bladder were 3.0% and 3.7% of the prescribed dose, respectively. Comparing the results of simulation using the interface software with those of simulation using the standard MCNP geometry entry showed a less than 1% difference of the prescribed dose at 67% of the studied points (minimum

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

ct-based brachytherapy treatment planning using monte carlo simulation aided by an interface software

introduction: in brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. this emphasizes the need for computerized treatment planning. the usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the manchester system. nowadays, because of their advantages ...

full text

An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions.

Certain brachytherapy dose distributions, such as those for LDR prostate implants, are readily modeled by treatment planning systems (TPS) that use the superposition principle of individual seed dose distributions to calculate the total dose distribution. However, dose distributions for brachytherapy treatments using high-Z shields or having significant material heterogeneities are not currentl...

full text

Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation

Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...

full text

BrachyGuide: a brachytherapy‐dedicated DICOM RT viewer and interface to Monte Carlo simulation software

This work presents BrachyGuide, a brachytherapy-dedicated software tool for the automatic preparation of input files for Monte Carlo simulation from treatment plans exported in DICOM RT format, and results of calculations performed for its benchmarking. Three plans were prepared using two computational models, the image series of a water sphere and a multicatheter breast brachytherapy patient, ...

full text

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

full text

Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations

Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three 60Co sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a go...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 8  issue 1

pages  41- 53

publication date 2011-03-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023