Abstract:
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference between each cardiac cycle and a relative pulse wave.Methods: Finger pulse and ECG signals in lead I were recorded by a monitoring device. The output of monitoring device is inserted in a computer by serial network communication. A software interface is used to display and process the signals in the computer. Time difference between each cardiac cycle and pulse signal was calculated throughout R wave detection in ECG and peak of pulse signal by the software. The relation between time difference in two waves and BP was determined then the coefficients of equation were obtained in different physical situations. The results of estimating BP were compared with the results of sphygmomanometer method and the error rate was calculated.Results: In this study, 25 subjects participated among them 15 were male and 10 were female. The results show that BP is linearly related to time difference. Average of coefficient correlation is 0.9±0.03 for systolic and 0.82±0.04 for diastolic blood pressure. The highest error percentage was calculated 8% for male and 11% for female group. Significant difference was observed between the different physical situation and arm movement changes. The relationship between time difference and age was estimated in a linear relationship with a correlation coefficient of 0.76.Conclusion: By determining linear relation values with high accuracy, BP can be measured with insignificant error. Therefore it can be suggested as a new method to measure the blood pressure continuously.
similar resources
continuous and cuffless blood pressure monitoring based on ecg and spo2 signals by using microsoft visual c sharp
background: one of the main problems especially in operating room and monitoring devices is measurement of blood pressure (bp) by sphygmomanometer cuff. objective: in this study we designed a new method to measure bp changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. this will be achieved by extraction of the time difference...
full textContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals ByUsing Microsoft Visual C Sharp
BACKGROUND One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff. Objective :In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...
full textDesigning and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...
full textCuffless Blood Pressure Estimation Based on Data-Oriented Continuous Health Monitoring System
Measuring blood pressure continuously helps monitor health and also prevent lifestyle related diseases to extend the expectancy of healthy life. Blood pressure, which is nowadays used for monitoring patient, is one of the most useful indexes for prevention of lifestyle related diseases such as hypertension. However, continuously monitoring the blood pressure is unrealistic because of discomfort...
full textdesigning and constructing an optical system to measure continuous and cuffless blood pressure using two pulse signals
introduction blood pressure (bp) is one of the important vital signs that need to be monitored for personal healthcare. arterial blood pressure is estimated from pulse transit time (ptt). this study uses two pulse sensors to get ptt. the aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. materials and m...
full textCuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals
Cardiovascular disease, like hypertension, is one of the top killers of human life and early detection of cardiovascular disease is of great importance. However, traditional medical devices are often bulky and expensive, and unsuitable for home healthcare. In this paper, we proposed an easy and inexpensive technique to estimate continuous blood pressure from the heart sound signals acquired by ...
full textMy Resources
Journal title
volume 4 issue 1
pages -
publication date 2014-03-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023