Comparison of ScintSim1 and Geant4 Monte Carlo simulation codes for optical photon transport in thick segmented scintillator arrays

Authors

  • Mohammad Amin Mosleh-Shirazi Ionizing and Non-Ionizing Radiation Protection Research Center, Shiraz University of Medical Sciences, Shiraz, Iran Physics Unit, Department of Radiotherapy and Oncology, Shiraz University of Medical Sciences, Shiraz, Iran
  • Sahar Ranjbar Department of Medical Physics and Engineering, Shiraz University of Medical Sciences, Shiraz, Iran
  • Sareh Karbasi Physics Unit, Department of Radiotherapy and Oncology, Shiraz University of Medical Sciences, Shiraz, Iran
  • Somayeh Gholami Radiotherapy Oncology and Radiobiology Research Center, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
  • Zinat Zarrini-Monfared Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
Abstract:

  Introduction: Arrays of segmented scintillation crystals are useful in megavoltage x-ray imaging detectors for image-guided radiotherapy. Most previous theoretical studies on these detectors have modelled only ionizing-radiation transport. Scintillation light also affects detector performance. ScintSim1, our previously reported optical Monte Carlo code for such detectors, includes the main optical processes of interest. Here, we benchmarked ScintSim1 against the more complex and extensive Geant4 optical Monte Carlo toolkit. We aimed to assess the importance of some simplifications made in ScintSim1 and gain further insight into the more relevant optical processes Materials and Methods: We used Geant4 (version 9.6. p02) in this study. As the aim of this study was to compare the simulation of optical photons in the two codes, dependence of the simulation results on x- ray and electron interactions had to be excluded. To compare the two models correctly, they had to have the same inputs. So, in both models, an equal number of light photons were generated at identical points, obtained from previously computed depth-dose distributions resulting from X-ray and electron interactions. We first performed various tests to check proper implementation of the Geant4 code then various optical results (such as numbers and distributions of incidences, absorption and reflection) were compared. In the second part of the study, Geant4 was used for coupled simulation of ionizing radiation (x-rays and electrons) and optical photon transport in the scintillator with a slit to obtain the ionizing- radiation-only line spread function (LSF) of the energy deposited in the elements and the number of optical photons incident on an underlying screen (‘full simulation’ including ionizing radiation and optical photons) for each case. A composite LSF was then calculated and compared with the corresponding optical results obtained by using ScinSim1 Results: The differences between the optical outputs of the two codes ranged between 0.1% and 1.7%. The full-width-at-half-maximum values of the LSF for energy deposited and total (ionizing + light) normalized LSFs from the two codes differed by only 0.01 mm and 0.1 mm, respectively. Using the same computer, the run time required to launch and simulate 108 optical photon histories (without any prior ionizing radiation transport) was 16 minutes in ScintSim1 and 421 minutes in Geant4. Conclusion: These results show a close agreement between the outputs of the two models for the studied conditions and suggest that the optical processes not modelled in ScintSim1 have little effect on the results required for detector optimization in megavoltage imaging using an array of segmented scintillation crystals. The model simplifications in ScintSim1 offer substantial run-time reductions if computational time-reduction methods are not used. Nonetheless, the developed Geant4 model is a powerful tool for further detector design parameter optimization.        

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Optical simulation of monolithic scintillator detectors using GATE/GEANT4.

Much research is being conducted on position-sensitive scintillation detectors for medical imaging, particularly for emission tomography. Monte Carlo simulations play an essential role in many of these research activities. As the scintillation process, the transport of scintillation photons through the crystal(s), and the conversion of these photons into electronic signals each have a major inf...

full text

Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams

Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...

full text

A GEANT4 Monte-Carlo Simulation Code for precision β spectroscopy

The measurement of the β asymmetry parameter in nuclear β decay is a potentially very sensitive tool to search for non V −A components in the charge-changing weak interaction. To reach the required precision (percent level) all effects that modify the emission pattern of the β radiation, i.e. the geometry of the setup, the effect of the magnetic field on the trajectories of β particles as well ...

full text

Radioiodine (131-I) treatment for Graves’ disease: Geant4 Monte Carlo simulation for patient personalized dose estimation

Background: Reliable estimation of radiation-absorbed dose is necessary to evaluate the benefits and the risks of radiopharmaceuticals used for diagnostic or therapeutic purposes in nuclear medicine. Materiel and Methods: This study included 47 patients treated with iodine-131 for Graves’ disease. A comparative study between Geant4 Monte Carlo simulation and MIRD formalism was carried out to ev...

full text

An Intra-comparison between Geant4-dna and a Variety of Monte Carlo Codes 2

20 Modelling the radio-induced effects in biological medium requires accurate physics models to 21 describe in detail the main physical interactions induced by all the charged particles present in 22 the irradiated medium (secondary as well as primary ones). These interactions include 23 inelastic events like ionization and excitation processes as well as elastic scattering, the latter 24 being...

full text

a comparison between gate and mcnpx monte carlo codes in simulation of medical linear accelerator

radiotherapy dose calculations can be evaluated by monte carlo (mc) simulations with acceptable accuracy for dose prediction in complicated treatment plans. in this work, standard, livermore and penelope electromagnetic (em) physics packages of geant4 application for tomographic emission (gate) 6.1 were compared versus monte carlo n-particle extended (mcnpx) 2.6 in simulation of 6 mv photon lin...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  218- 218

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023