Comparison of Radiopacity of Six Endodontic Sealers

Authors

  • Ayub Habibi Dental Material Research Center
  • Farida Abesi Dental Material Research Center Department of Oral and Maxillofacial Radiology, Babol University of Medical Sciences, Babol, Iran.
  • Mahtab Hamzeh Dental Material Research Center Babol University of Medical Sciences, Babol, Iran.
  • Maryam Ehsani Dental Material Research Center, Department of endodontics, Babol University of Medical Sciences, Babol, Iran
  • Sina Haghanifar Dental Material Research Center Department of Oral and Maxillofacial Radiology, Babol University of Medical Sciences, Babol, Iran.
  • Sorayya Khafri Department of Social Medicine, Babol University of Medical Sciences, Babol, Iran.
Abstract:

Introduction: Optimal radiopacity is one of the properties required for a root canal sealer that helps the distinction between the sealer and surrounding anatomic structures and evaluation of the quality of root filling. So, the purpose of this study was to evaluate the radiopacity of six root canal sealers at different focal distances. Materials and Methods: In this in vitro study, six endodontic sealers (ADSEAL, AH26, AH plus, Dorifill, MTA fillapex, and ZOE), were prepared and placed in a mold with 1mm thickness and 10mm diameter. The specimens were posi-tioned alongside an aluminum step wedge on a digital detector (occlusal size 76×57 mm). Radi-ographic imaging was performed at 15 and 30cm focal distances and radiopacity of each specimen was measured.One-way ANOVA and paired t-test were used and p<0.05 was consi-dered significant. Results: All sealers were found to be more radiopaque than 3 mm aluminum. At 15cm focal distance, the radiopacity values were 31.7, 60.68, 121.48, 52.4, 48.6, and 48.08 aluminum for ADSEAL, AH26, AH plus,Dorifill, MTA fillapex and ZOE, respectively. At 30cm focal distance, the figures were 80.32, 153.6, 253.6, 139.92, 144.08, and 129.92 for ADSEAL, AH26, AH plus,Dorifill, MTA fillapex and ZOE, respectively. Conclusion: All of the sealers investigated in this study met the standards for minimal radiopacity. AH plus had the highest radiopacity at both focal distances. Radiopacity decreased by increasing the focal distance and the decline was statistically significant for AHplus.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

comparison of radiopacity of six endodontic sealers

introduction: optimal radiopacity is one of the properties required for a root canal sealer that helps the distinction between the sealer and surrounding anatomic structures and evaluation of the quality of root filling. so, the purpose of this study was to evaluate the radiopacity of six root canal sealers at different focal distances. materials and methods: in this in vitro study, six endodon...

full text

Radiopacity and flow of different endodontic sealers.

The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10 mm in diameter and 1 mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determin...

full text

Comparison of Endodontic Sealers in Terms of Their Sealing Ability

The purpose of this in vitro study was to compare the apical sealing ability of mineral trioxide aggregate and glass ionomer cement by a dye penetration test. It was carried out at Queen Marry and Westfield College, University of London during 2010-2011 session. Time duration was 6 months. A total of 16 samples of elephant tusk dentine (ivory) were prepared and finished for dye penetration test...

full text

Ex Vivo Comparison of the Discoloration Potential of Two Endodontic Sealers in Human Incisors

Background and Aim: Tooth discoloration induced by endodontic materials is a common finding which can impair the aesthetic outcome. The aim of this study was to compare the coronal discoloration induced by Well-Root ST and AH26 root canal sealers by using the Easyshade® colorimeter. Materials and Methods: Forty-five intact maxillary central incisors were involved in this experimental study. Th...

full text

Cytotoxicity evaluation of four endodontic sealers.

This study evaluated in vitro the cytotoxicity of four root canal sealers (Topseal, EndoRez, TubliSeal and Kerr Pulp Canal Sealer E.W.T.) and their effects on reactive oxygen/nitrogen intermediate induction by mouse peritoneal macrophages. Thioglycollate-induced cells were obtained from Swiss mice by peritoneal lavage with 5 mL 10 mM phosphate-buffered saline, washed twice and resuspended (10(6...

full text

Colorimetric Comparison of Tooth Color Change Following the Use of Two Endodontic Sealers: An Ex-Vivo Study

Background and Aim: Tooth discoloration induced by endodontic sealers is an un-desired outcome of endodontic treatment that affects the esthetic appearance of the teeth, which is important especially in the anterior region. The aim of the present study was to compare the coronal discoloration caused by two frequently used resin-based sealers namely EasySeal and AdSeal. Materials and Methods: F...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 2  issue 2

pages  23- 27

publication date 2013-08

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023