Comparison of new optical sensor based on triazene ligand immobilized on PVC and triacetylcellulose membranes for Hg (II) Ion

Authors

  • Homa Shafiekhani Department of Chemistry, Payame Noor University (PNU), 19395-4697 Tehran, Iran
  • Shahriyar Bahar Department of Chemistry, Payame Noor University (PNU), 19395-4697 Tehran, Iran
  • Zoheir Hagh’goo Department of Chemistry, Lamerd Branch, Islamic Azad university, Lamerd, Iran
Abstract:

For spectrophotometric analysis of Hg (II) ions, we have used and compared two membranes preparation methods using different polymer; one is poly(vinyl chloride) (PVC) and the other is triacetylcellulose (TAC). In the case of TAC membrane, it was treated with a ligand solution (1.166 × 10-3 mole L-1) in ethylenediamine at the ambient temperature for almost 2-5 min. However, in the case of PVC membrane, the ligand of triazen was incorporated into a plasticized membrane of PVC. The significant factors affecting the determination of analytical performance from aqueous solutions, limit of detections (LODs) by TAC membrane (64 µg L-1) and by PVC membrane (0.069 ng L-1), linear dynamic range (DLR) by TAC membrane (7-90 mg L-1) and by PVC membrane (0.125-10 µg L-1). In this work LODs and linear dynamic range of PVC membrane is lower than of TAC membrane by a factor of 10000. However, TAC membrane was easier to operate and no more special device required, but PVC membrane required much shorter time reaching to steady state. Two membranes were successfully applied to the determination of Hg (II) in water samples.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

on the comparison of keyword and semantic-context methods of learning new vocabulary meaning

the rationale behind the present study is that particular learning strategies produce more effective results when applied together. the present study tried to investigate the efficiency of the semantic-context strategy alone with a technique called, keyword method. to clarify the point, the current study seeked to find answer to the following question: are the keyword and semantic-context metho...

15 صفحه اول

application of upfc based on svpwm for power quality improvement

در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...

15 صفحه اول

An optical sensor for mercuric ion based on immobilization of Rhodamine B derivative in PVC membrane.

A novel prepared mercuric ion PVC membrane sensor based on a Rhodamine B derivative (RND) as a selective sensing material was described. The sensor exhibited a specific fluorescent off-on response to Hg(2+), and showed a linear response over the Hg(2+) concentration range from 1.0 × 10(-9) to 2.0 × 10(-3)M with a very low detection limit of 8.1 × 10(-10)M in bulk method. The sensor has also bee...

full text

A PVC plasticized sensor for Ni(II) ion based on a simple ethylenediamine derivative.

A new PVC membrane ion selective electrode which is highly selective towards Ni(II) ions was constructed using a Schiff base containing a binaphthyl moiety as the ionophore. The sensor exhibited a good Nernstian response for nickel ions over the concentration range 1.0x10(-1)-5.0x10(-6) M with a lower limit of detection of 1.3x10(-6) M. It has a fast response time and can be used for a period o...

full text

synthesis and characterization of some new cyclometalated organoplatinum(ii) complexes containing phosphite ligand

در این تحقیق روشی جهت سنتز یک سری از کمپلکس های پلاتین (ii) حاوی لیگاند های دهنده ی فسفری شامل فسفیت و فسفین ارائه شده است. واکنش پیش ماده ی پلاتین (ii)،trans/cis- [ptcl2(sme2)2] ، با 2 اکی مولار از لیگاند p(oph)3در حلال بنزن کمپلکس1، cis-[ptcl2(p(oph)3)2] را تولید می نماید. جهت سنتز کمپلکس سایکلو متال فسفیتی، کمپلکس 1 با 1 اکی والان واکنشگر ptcl2 در حلال زایلن در شرایط رفلاکس زیر گاز آرگون م...

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 7  issue Issue 1, pp. 1-124

pages  102- 112

publication date 2019-01-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023