Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Authors
Abstract:
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TKA were compared to the results of conventional instrumentation (CVI) TKA. The guideswere designed on the basis of distal femoral and proximal tibial pin orientation of the conventional related guides.Methods: The present study was carried out on 24 TKA candidates randomly assigned to two PSI (n=12) and CVI(n=12) groups. The patients were postoperatively followed for 2 years. Then, the hip-knee-ankle angle (HKAA), femoralcomponent flexion, and orientation of components in the coronal plane were measured. In addition, the WesternOntario and McMaster Universities Osteoarthritis (WOMAC) Index and Knee Society Score (KSS) questionnaire werecompleted for all the patients.Results: The rate of the outliers of the HKAA was higher in the CVI group (41.7% and 8.3%; P=0.077); nevertheless,the difference was not significant in this regard. The rate of the outliers of other radiographic measurements andoperational time were similar in both groups. Furthermore, there was no significant difference between the two groupsin terms of the WOMAC and KSS.Conclusion: The CT-based PS-guided TKA may result in the improved postoperative mechanical alignment of the limband should be considered in complicated TKAs. However, future studies should investigate whether the results of PSITKA support the considerably higher costs of this technique.Level of evidence: II
similar resources
[Meta analysis of three-dimensional printing patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty].
Objective: To evaluate the effects of three-dimensional printing patient-specific instrumentation(PSI) versus conventional instrumentation(CI) in the total knee arthroplasty. Methods: According to "patient-specific" , "patient-matched" , "custom" , "Instrumentation" , "Guide Instrumentation" , "cutting blocks" , "total knee arthroplasty" , "total knee replacement" , "TKA" and "TKR" , the litera...
full textAccuracy of patient-specific instrumentation compared with conventional instrumentation in total knee arthroplasty.
Patient-specific instrumentation (PSI) has recently been introduced to improve the alignment following total knee arthroplasty (TKA). However, controversy remains between PSI and conventional instrumentation. The aim of this study is to compare the accuracy of PSI with conventional instruments for total knee arthroplasty (TKA). A systematic literature search was performed in databases including...
full textMidterm Clinical and Radiological Outcomes of Total Knee Arthroplasty
Date of acceptance / Kabul tarihi: March 15, 2016 / 15 Mart 2016 ABSTRACT: Midterm clinical and radiological outcomes of total knee arthroplasty Purpose: The aim of this study is to investigate retrospectively the midterm clinical and radiological outcomes of total knee arthroplasty (TKA) which were performed in our clinic. Method: Thirty-one (27 women, 4 men) of 54 patients were included in th...
full textPatient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty
Background and purpose - Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) has been introduced to improve alignment and reduce outliers, increase efficiency, and reduce operation time. In order to improve our understanding of the outcomes of patient-specific instrumentation, we conducted a meta-analysis. Patients and methods - We identified randomized and quasi-randomized...
full textComparison of functional and radiological outcomes after computer-assisted versus conventional total knee arthroplasty: a matched-control retrospective study.
PURPOSE To compare the radiological and functional outcomes of patients who underwent either computer-assisted or conventional total knee arthroplasty (TKA). METHODS Two groups of 50 patients each underwent either computer-assisted or conventional TKA were retrospectively studied. Patients were matched according to body mass index (BMI), gender, and age. Three senior orthopaedic surgeons with...
full textPatient-Specific CT-Based Instrumentation versus Conventional Instrumentation in Total Knee Arthroplasty: A Prospective Randomized Controlled Study on Clinical Outcomes and In-Hospital Data
Total knee arthroplasty (TKA) is a frequently performed procedure in orthopaedic surgery. Recently, patient-specific instrumentation was introduced to facilitate correct positioning of implants. The aim of this study was to compare the early clinical results of TKA performed with patient-specific CT-based instrumentation and conventional technique. A prospective, randomized controlled trial on ...
full textMy Resources
Journal title
volume 8 issue 5
pages 625- 632
publication date 2020-09-01