Comparison of canal transportation after preparation by 3 different rotary systems
Authors
Abstract:
Comparison of canal transportation after preparation by 3 different rotary systems Dr. Javidi, M.* - Dr. Zarei, M.* - Dr. Vatanpour, M.** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Tehran Azad University. Abstract Background & Aim: Cleaning and shaping has been recognized as one of the most important steps of root canal treatment. Various Ni-Ti rotary systems have been introduced for reduction of complications and facilitating the root canal shaping process. The purpose of this study was to determine the amount of transportation by using the three rotary systems, Profile, Flex master and Race. Materials & Methods: This ex-vivo randomized controlled trial was carried out on mesial mandibular root canals (type3 Weine) with mild curvature (15-35o). The roots were randomly divided into three groups of 20 canals each. The roots were sectioned horizontally at 3mm, 6mm from the apex and then, reassembled before instrumentation according to the manufacture's guidelines. Photographs were taken from the cross sections before and after instrumentation. Image analyses were performed by Photoshop software, version 8. The ability to preserve canal shape centrally as well as the direction of transportation was determined next. Data was analyzed by ANOVA and Tukey tests. Results: The difference was significant in mid apical parts when comparing the three groups. Most transportation was in the furcation area. Race had the most and profiles showed the least transportation in both parts of the roots (P=0.001). Conclusion: The profile system was found to be the best for preserving the centering position of the root canal among the three rotary systems. Key words: Rotary systems - Transportation - Root canal preparation Corresponding Author: Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. e.mail:[email protected]
similar resources
Root Canal Surface Strain and Canal Center Transportation Induced by 3 Different Nickel-Titanium Rotary Instrument Systems.
INTRODUCTION Root canal anatomy and canal preparation instruments affect the outcome of endodontic treatment. The purpose of this study was to determine the root surface strain (SS) generated and the extent of canal center transportation during canal shaping using 3 different nickel-titanium instruments. METHODS Simulated root canals in resin blocks (n = 10 per group) were prepared using adap...
full textComparison of Canal Transportation, Centering Ratio by Cone-beam Computed Tomography after Preparation with Different File Systems.
AIM One Shape Apical 1 (OSA 1) is a new file for preparing the apical aspect of the root canal after One Shape (OS, Micro Mega, Besançon, France). This study compared apical transportation and centering ratios in curved root canals, which were instrumented with ProTaper Next (PTN, Dentsply Tulsa Dental Specialties, Tulsa, OK) up to size X3 and with OS up to OSA 1. MATERIALS AND METHODS Forty-...
full textCone-Beam Computed Tomography Comparison of Canal Transportation after Preparation with BioRaCe and Mtwo Rotary Instruments and Hand K-Flexofiles
INTRODUCTION The aim of this in vitro study was to evaluate the transportation of mesiobuccal canals of mandibular first molars prepared with either BioRaCe or Mtwo rotary instruments or hand K-Flexofile, by means of cone-beam computed tomography (CBCT). METHODS AND MATERIALS Forty-five mandibular molars were selected and randomly divided into three groups (n=15). Mesiobuccal roots of these t...
full textA comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro)
A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro) Dr. MR. Sharifian* - Dr. MH. Nekoofar* - Dr. P. Motahari** - Dr. A. Tavakoli*** *-Assistant Professor of Endodontics Dept. – Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Oral and Maxillofacial Pathology Dept. – Facul...
full textComparison of Two Canal Preparation Techniques Using Mtwo Rotary Instruments
INTRODUCTION Root canal preparation is an important process in endodontic therapy. Nickel-titanium (NiTi) rotary file system can be used in single length technique (simultaneous technique) without early coronal enlargement, as well as in crown-down method. The purpose of this in vitro study was to compare single length with crown-down methods' shaping ability using Mtwo NiTi files. MATERIALS ...
full textcone-beam computed tomography comparison of canal transportation after preparation with biorace and mtwo rotary instruments and hand k-flexofiles
introduction: the aim of this in vitro study was to evaluate the transportation of mesiobuccal canals of mandibular first molars prepared with either biorace or mtwo rotary instruments or hand k-flexofile, by means of cone-beam computed tomography (cbct). methods and materials: forty-five mandibular molars were selected and randomly divided into three groups ( n =15). mesiobuccal roots of these...
full textMy Resources
Journal title
volume 19 issue 4
pages 97- 102
publication date 2008-03
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023